TM1998_Stride Board Buffering Function.pdf - 第7页

 SMT Software Engineeri ng Group  IMOperationsYAMAHAMOTORCO. ,LTD.   MDOC-SOFT 50038-001  7/12 Ea29556 CONVEYORINTERLOC KERROR The entrance sensor at the l ow er mach ine was dete c…

100%1 / 12
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50038-0016/12
6.Errormessages
Table5.1Errormessages
Error No Content and cause Check point
Ea2201
BOARDTRANSFERERROR
Unexpected Board is on the conveyor.
On the auto-running or the transfer, two
boards are detected at the same time.
When the stopper of the mount position is
going to rise during sync transfer, this error
occurs when the next board arrives at the
mount position.
Please
move the boards to the transfer
destination position and restart
auto-running.
When this error occurs many times, please
input a value bigger than the present value
on the machine setting [Setting] –
[Mechanical] – [Position] – [Fast Trans Delay
Timer] (note 1).
Ea3976
WARNING:StrideBoardBuffering
UpperSetting
The setting of "Upper Handling" is not
"ADVANCED_GATE" though the setting of
"Stride Board Buffering(Upper)" is "Enable".
It needs to be set "ADVANCED_GATE" so
that "Stride Board Buffering(Upper)" works
effectively.
Please confirm the settings are set as
follows.
1. [Setting] - [Installation Setting] - [Upper
Handling] : ADVANCED_GATE
2. [Setting] - [Installation Setting] - [Stride
Board Buffering(Upper)] : Enable
Ea3977
WARNING:StrideBoardBuffering
LowerSetting
The setting of "Lower Handling" is not
"ADVANCED_GATE" though the setting of
"Stride Board Buffering(Lower)" is "Enable".
It needs to be set "ADVANCED_GATE" so
that "Stride Board Buffering(Upper)" works
effectively.
Please confirm the settings are set as
follows.
1. [Setting] - [Installation Setting] - [Lower
Handling] : ADVANCED_GATE
2. [Setting] - [Installation Setting] - [Stride
Board Buffering(Lower)] : Enable
Ea7336
Unknownboardisdetectedatthewait
positionsensor
Unknown board is detected at the wait
position sensor.
The board exists though the wait positions
stopper doesn’t rise.
Please remove the board on the wait
position, and restart auto-running.
Please insert the board into the wait position
again after a board in the machine is carried
out.
Ea7337
BOARDTRANSFERERROR
The board transfer to lower machine was
failed.
The board may be caught between
machines.
Please move the board to the
board fixing
position of the downstream machine, and
start auto-running.
Ea7338
Unknownboardisdetectedattheexit
positionsensor.
Unknown board is detected at the exit
position sensor.
When the board is not necessary for the
production, please remove the board and
restart auto-running.
When the board is produced by inserting the
board to the wait position of the downstream
machine, please operate the following
procedures.
1. Reset the downstream machine and this
machine.
2. Press the [EMERGENCY STOP] button of
the downstream machine and this machine.
3. Insert the board from the exit position of
this machine to the wait position of the
downstream machine.
4. Restart auto-running.
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50038-0017/12
Ea29556
CONVEYORINTERLOCKERROR
The entrance sensor at the lower machine
was detected.
There is possibility that the board exist
between machines.
When the function of “Stride Board
Buffering” is effective, W Axis cannot be
moved.
Please press the [EMERGENCY STOP]
button of the downstream machine and this
machine, and remove the board of
the “the
board wait striding the machine” state
.
When the downstream machine was turned
off, please turn on the machine.
Note.1 The
[Fast Trans Delay Timer] setting value is the timer to delay the transfer start timing of the
upstream board at sync transfer. The suitable values are different in the chattering timer, the conveyer
speed, the line constitution, etc.
When these errors occur, please set each 30msec big value than a
present value, and confirm the operating properly.
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50038-0018/12
7.Appendix
7.1.Automaticsettings
The work of this chapter is not necessary unless line constitution is changed.
The following setting is necessary when line constitution is changed or when upstream /
downstream machine is changed. However, the mechanical change of the conveyor in
upstream machine or this machine or downstream machine exists, please refer to "Chapter.7.2.
Manual Settings".
Please tap on [VmSpec] – [Toolbar] – [Stride Board Buffering Setting] button (See Fig.7.1).
When it is taped, [Stride Board Buffering Setting] screen opens.
Fig.7.1VmSpecScreen