TM1998_Stride Board Buffering Function.pdf - 第8页

 SMT Software Engineeri ng Group  IMOperationsYAMAHAMOTORCO. ,LTD.   MDOC-SOFT 50038-001  8/12 7. A p pendix 7.1. Auto m aticsettings The work of this chapter is not necessar y unl…

100%1 / 12
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50038-0017/12
Ea29556
CONVEYORINTERLOCKERROR
The entrance sensor at the lower machine
was detected.
There is possibility that the board exist
between machines.
When the function of “Stride Board
Buffering” is effective, W Axis cannot be
moved.
Please press the [EMERGENCY STOP]
button of the downstream machine and this
machine, and remove the board of
the “the
board wait striding the machine” state
.
When the downstream machine was turned
off, please turn on the machine.
Note.1 The
[Fast Trans Delay Timer] setting value is the timer to delay the transfer start timing of the
upstream board at sync transfer. The suitable values are different in the chattering timer, the conveyer
speed, the line constitution, etc.
When these errors occur, please set each 30msec big value than a
present value, and confirm the operating properly.
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50038-0018/12
7.Appendix
7.1.Automaticsettings
The work of this chapter is not necessary unless line constitution is changed.
The following setting is necessary when line constitution is changed or when upstream /
downstream machine is changed. However, the mechanical change of the conveyor in
upstream machine or this machine or downstream machine exists, please refer to "Chapter.7.2.
Manual Settings".
Please tap on [VmSpec] – [Toolbar] – [Stride Board Buffering Setting] button (See Fig.7.1).
When it is taped, [Stride Board Buffering Setting] screen opens.
Fig.7.1VmSpecScreen
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50038-0019/12
Fig7.2StrideBoardBufferingSetting
Please set it in the following procedures with [Stride Board Buffering Setting] screen (See
Fig.7.2).
1. Set “Enable” on [Stride Board Buffering Lower] and [Stride Board Buffering Upper] comb
box.
The following settings are set on [Setting] - [Installation Setting] - [Software].
1) [Stride Board Buffering(Upper)] or [Stride Board Buffering(Lower)] is set to “Enable”.
2) [Upper Handling] or [Lower Handling] is set to “ADVANCED GATE”.
2. Set the settings on [Lower Machine Type], [Own Machine Type] and [Upper Machine Type].
Please choose the downstream machine, this machine, upstream machine from the combo
box. The following settings at [Machine data] - [Mechanical] - [Position] - [Stride Board
Buffering] are set
1) [Upper Machine Max Board Size]
2) [Lower Machine Min Board Size]
3) [Lower Machine Max Board Size]
When the machine type that you want to choose is not displayed at the combo box, please
set “Disable” on [Stride Board Buffering –Lower] or [Stride Board Buffering – Upper].
1
1
2
2 2