32 SOM-2080 Erroe ID Error Name, Description, Cause, and Remedy 425213 Output Cnvr PCB Detection PCB on a conveyer was removed in output sync / alternation output process. Please do reproduction after making the P.C.B re…

100%1 / 179
31
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
425201 Output Cnvr PCB Detection
PCB's were at inlet and outlet of cnvr.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425202 Output Cnvr PCB Detection
There is no PCB on the Cnvr The PCB fell while moving to the receiving position.
Please continue production after checking whether the P.C.B has fallen around a
conveyor. Moreover, please execute the zeroing operation of a pertinent conveyer
from the screen of maintenance/unit adjustment/conveyer when the width of the
conveyer has changed.
425203 Output Cnvr PCB Detection
There is no PCB on the Cnvr The PCB was removed.
-----
425204 Output Cnvr PCB Detection
There is a PCB on the Cnvr The PCB could not be discharged.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425205 Output Cnvr PCB Detection
There is no PCB on the conveyer. After the PCB carrying in ended, it can not able
to be detected.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425206 Output Cnvr PCB Detection
The PCB was detected by the conveyer entrance sensor.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425207 Output Cnvr PCB Detection
The PCB was detected with the conveyer exit sensor.
Please confirm the P.C.B on the conveyer.
425208 Output Cnvr PCB Detection
The exhaust end board sensor of a conveyor exit detected the PCB
Please check the P.C.B on a conveyor.
425209 Output Cnvr PCB Detection
The exhaust end board sensor of a conveyor exit did not detect PCB during
discharge operation.
Please check the sensor.
425210 Output Cnvr PCB Detection
Manual bypass of the PCB was carried out in the state where a PCB is on a
conveyor.
Please remove the P.C.B carried out manual bypass. Production can be
continued.
425211 Output Cnvr PCB Detection
The PCB was not found in the proper position.
Please remove the P.C.B on a conveyor. Production can be continued.
425212 Output Cnvr PCB Detection
Manual bypass of the PCB was carried out.
Please remove the P.C.B carried out manual bypass. Production can be
continued.
6.3 Conveyor
1005-001
32
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
425213 Output Cnvr PCB Detection
PCB on a conveyer was removed in output sync / alternation output process.
Please do reproduction after making the P.C.B return to original state.
425214 Output Cnvr PCB Detection
The state of a PCB on conveyer changed in output sync / alternation output
process.
Please do reproduction after making the P.C.B return to original state.
425215 Output Cnvr PCB Detection
The PCB was detected with the conveyer entrance sensor.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly
425216 Output Cnvr PCB Detection
The PCB was detected before carrying-in operation.
Restart the product operation after removing the P.C.B. when it is on the
conveyor.
425217 Output Cnvr PCB Detection
A PCB was detected with the conveyor entrance sensor upon completion of the
output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
425218 Output Cnvr PCB Detection
A PCB was detected with the conveyor exit sensor upon completion of the output
operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
425219 Output Cnvr PCB Detection
A PCB was detected with the both sensors of the conveyor entrance and exit
upon completion of the output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
425220 Output Cnvr PCB Detection
The machine let the END PCB remove from the conveyor.
Put the P.C.B. on the output conveyor and perform the "START". The product
operation can be continued that why the machine considers as if the P.C.B. put
was the end P.C.B..
425301 Output Cnvr Error
The carrying in operation was not able to begin.
-----
425302 Output Cnvr Error
The error was detected while carrying in was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
6.3 Conveyor
1005-001
33
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
425303 Output Cnvr Error
The exhaust operation was not able to begin.
-----
425304 Output Cnvr Error
The error was detected while exhaust was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425305 Output Cnvr Error
The PCB transport to receiving position was not able to begin.
-----
425306 Output Cnvr Error
The error was detected while transpoting to the receiving position.
-----
425307 Output Cnvr Error
The operation moving to the arrangement position was not able to begin.
-----
425308 Output Cnvr Error
The error was detected while transporting to the arrangement position.
-----
425309 Output Cnvr Error
The reversal positioning operation was not able to begin.
-----
425310 Output Cnvr Error
The error was detected while the reversal positioning was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425311 Output Cnvr Error
Conveyor width The conveyor upper cover by output side opened during axial
operation.
Please close a cover and perform again.
425312 Output Cnvr Error
The conveyor upper cover by output side opened during production operation and
equipment operation.
Please close a cover and perform again.
425313 Output Cnvr Error
The Output conveyor upper cover opened during production operation and
equipment operation.
Please close a cover and perform again.
425314 Output Cnvr Error
It changed into the conveyor operation forbidden state during axial operation of
conveyor width. (The conveyor operation forbidden signal from output conveyor
was detected.)
Please cancel the forbidden operation state of a conveyor and perform again.
6.3 Conveyor
1005-001