SOM-2080-001_w.pdf - 第36页
33 SOM-2080 Erroe ID Error Name, Description, Cause, and Remedy 425303 Output Cnvr Error The exhaust operation was not able to begin. ----- 425304 Output Cnvr Error The error was detected while exhaust was operating. Por…

32
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
425213 Output Cnvr PCB Detection
PCB on a conveyer was removed in output sync / alternation output process.
Please do reproduction after making the P.C.B return to original state.
425214 Output Cnvr PCB Detection
The state of a PCB on conveyer changed in output sync / alternation output
process.
Please do reproduction after making the P.C.B return to original state.
425215 Output Cnvr PCB Detection
The PCB was detected with the conveyer entrance sensor.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly
425216 Output Cnvr PCB Detection
The PCB was detected before carrying-in operation.
Restart the product operation after removing the P.C.B. when it is on the
conveyor.
425217 Output Cnvr PCB Detection
A PCB was detected with the conveyor entrance sensor upon completion of the
output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
425218 Output Cnvr PCB Detection
A PCB was detected with the conveyor exit sensor upon completion of the output
operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
425219 Output Cnvr PCB Detection
A PCB was detected with the both sensors of the conveyor entrance and exit
upon completion of the output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
425220 Output Cnvr PCB Detection
The machine let the END PCB remove from the conveyor.
Put the P.C.B. on the output conveyor and perform the "START". The product
operation can be continued that why the machine considers as if the P.C.B. put
was the end P.C.B..
425301 Output Cnvr Error
The carrying in operation was not able to begin.
-----
425302 Output Cnvr Error
The error was detected while carrying in was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
6.3 Conveyor
1005-001

33
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
425303 Output Cnvr Error
The exhaust operation was not able to begin.
-----
425304 Output Cnvr Error
The error was detected while exhaust was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425305 Output Cnvr Error
The PCB transport to receiving position was not able to begin.
-----
425306 Output Cnvr Error
The error was detected while transpoting to the receiving position.
-----
425307 Output Cnvr Error
The operation moving to the arrangement position was not able to begin.
-----
425308 Output Cnvr Error
The error was detected while transporting to the arrangement position.
-----
425309 Output Cnvr Error
The reversal positioning operation was not able to begin.
-----
425310 Output Cnvr Error
The error was detected while the reversal positioning was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425311 Output Cnvr Error
Conveyor width The conveyor upper cover by output side opened during axial
operation.
Please close a cover and perform again.
425312 Output Cnvr Error
The conveyor upper cover by output side opened during production operation and
equipment operation.
Please close a cover and perform again.
425313 Output Cnvr Error
The Output conveyor upper cover opened during production operation and
equipment operation.
Please close a cover and perform again.
425314 Output Cnvr Error
It changed into the conveyor operation forbidden state during axial operation of
conveyor width. (The conveyor operation forbidden signal from output conveyor
was detected.)
Please cancel the forbidden operation state of a conveyor and perform again.
6.3 Conveyor
1005-001

34
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
425315 Output Cnvr Error
The PCB was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught. Please confirm it over a conveyer. Moreover, please execute the zeroing
operation of a pertinent conveyer from the screen of maintenance/unit adjustment/
conveyer when the width of the conveyer has changed.
425316 Output Cnvr Error
Abnormality occurred at the time of disposal of Board END signals.
Please start production again.
425317 Output Cnvr Error
The process of inside signal between conveyors failed.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425318 Output Cnvr Error
Speed reduction was not performed during transferring operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
426101 Input Conveyor Error
The initialization is imperfect.
-----
426102 Input Conveyor Error
An error occurred during zeroing operation.
Try to operate the zero return again.
426103 Input Conveyor Error
An alarm for interference is occurring.
-----
426104 Input Conveyor Error
DI was detected.
-----
426105 Input Conveyor Error
The input conveyor upper cover opened during product operation or the machine
running.
-----
426106 Input Conveyor Error
Brownout on the power source was detected.
Confirm the transfer driver.
426107 Input Conveyor Error
OT(+) was detected during product operation or the machine running.
Operate the zero return for the conveyor.
426108 Input Conveyor Error
OT(-) was detected during product operation or the machine running.
Operate the zero return for the conveyor.
6.3 Conveyor