45 SOM-2080 Erroe ID Error Name, Description, Cause, and Remedy 431804 Tray Feeder in advance check error Traverse axis main circuit was cut off ----- 431805 Tray Feeder in advance check error Safety circuit cut off ----…

44
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
431637 Tray Feeder Zeroing Error
The tray resupply traverse cannot detect the pallet. Open the resupply cover and
check the pallet conditions. [B6215]
-----
431638 Tray Feeder Zeroing Error
The tray resupply traverse has a history of drawing but the detection is impossible.
[B6215]
The drawing history was cleared. Perform the zeroing operation again.
431639 Tray Feeder Zeroing Error
The tray resupply traverse has no history of drawing but a pallet was detected.
[B6215]
Remove the pallet and perform the zeroing operation again.
43163a Tray Feeder Zeroing Error
Tray resupply door power lock OPEN
-----
43163b Tray Feeder Zeroing Error
The rack shutter on the lower magazine operator side could not be opened on
time. [B6221]
-----
43163c Tray Feeder Zeroing Error
The rack shutter on the upper magazine operator side could not be opened on
time. [B6223]
-----
43163d Tray Feeder Zeroing Error
The rack shutter on the lower magazine operator side could not be closed on
time. [B6221]
-----
43163e Tray Feeder Zeroing Error
The rack shutter on the upper magazine operator side could not be closed on
time. [B6223]
-----
43163f Tray Feeder Zeroing Error
Tray resupply traverse pallet chuck unclamped error
-----
431801 Tray Feeder in advance check error
Tray power supply unturning on(power supply cut off from main machine)
-----
431802 Tray Feeder in advance check error
Main machine safety cover OPEN
-----
431803 Tray Feeder in advance check error
Tray maintenance cover OPEN
-----
6.4 Tray Feeder
1005-001

45
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
431804 Tray Feeder in advance check error
Traverse axis main circuit was cut off
-----
431805 Tray Feeder in advance check error
Safety circuit cut off
-----
431806 Tray Feeder in advance check error
Elevator axis main circuit cut off
-----
431807 Tray Feeder in advance check error
Upper/Lower Door Solenoid Lock OPEN
-----
431808 Tray Feeder in advance check error
Middle Door Solenoid Lock OPEN
-----
431809 Tray Feeder in advance check error
Others
-----
43180a Tray Feeder in advance check error
Others
-----
43180b Tray Feeder in advance check error
Others
-----
43180c Tray Feeder in advance check error
Others
-----
43180d Tray Feeder in advance check error
Traverse axis Servo OFF
-----
43180e Tray Feeder in advance check error
Traverse axis Servo Alarm
-----
43180f Tray Feeder in advance check error
Elevator axis Servo OFF
-----
431810 Tray Feeder in advance check error
Elevator axis Servo Alarm
-----
431811 Tray Feeder in advance check error
Mis-Pick-up comp. Detection 8mm[B0417]
-----
431812 Tray Feeder in advance check error
Mis-Pick-up comp. Detection 14mm[B0418]
-----
6.4 Tray Feeder
1005-001

46
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
431813 Tray Feeder in advance check error
Mis-Pick-up comp. Detection 28mm[B0419]
-----
431814 Tray Feeder in advance check error
Pallet chuck is not shut
-----
431815 Tray Feeder in advance check error
The pallet Mis-Set was detected.
-----
431816 Tray Feeder in advance check error
Magazine clamp OPEN
-----
431817 Tray Feeder in advance check error
Rack shutter OPEN
-----
431818 Tray Feeder in advance check error
Magazine location confirmation
-----
431819 Tray Feeder in advance check error
Elevator axis safety relay
-----
43181a Tray Feeder in advance check error
Others
-----
43181b Tray Feeder in advance check error
Pallet in the Return Position[B0518 B0519]
-----
43181c Tray Feeder in advance check error
Others
-----
43181d Tray Feeder in advance check error
Others
-----
43181e Tray Feeder in advance check error
Others
-----
43181f Tray Feeder in advance check error
Check error before tray feeder operation
-----
431820 Tray Feeder in advance check error
Zeroing incomplete
-----
431821 Tray Feeder in advance check error
A emergency stop was detected in the main machine.
-----