3.3 Error IDs and Remedial Procedures Error ID ltem Description 660301 Head Skip Communication Error 660302 Head Skip Head Origin 660303 Head Skip Overtime Head Origin Return 660304 Head Skip Unselected Nozzle Drop 66030…

3.3 Error IDs and Remedial Procedures
Error ID ltem Description
660206 Nozzle Skip Nozzle Level
(Cause 1) This error occurs when the L value exceeds the tolerance in comparison with the
master nozzle in the offset data.
(Remedy 1) Check if a big value is set as an L level of the master nozzle in the offset data.
Check if the nozzle is broken or dirt adheres to the end.
660207 Nozzle Skip Nozzle Drop
(Cause 1) When a "NOZ. DOWN ERR (L)" error occurs, the nozzle is bypassed and the nozzle
bypass data indicates that "BYPASSED" appears as a low nozzle item.
(Remedy 1) Open the "Head/Noz. Bypass" tab sheet in the "OPN. MODE" window (submenu)
and press the [Reset Noz. Bypass] button. The "Bypass" in the "Nozzle Height"
text box disappears, indicating that "Bypass" is canceled.
660208 Nozzle Skip Dummy Nozzle
660209 Nozzle Skip Manual Bypass
(Cause 1) This appears when some nozzles are bypassed manually.
(Remedy 1) When the [Reset Noz. Bypass] button is pressed in the "Head/Noz. Bypass" tab
sheet of the "OPN. MODE" window (submenu), the manual bypass designation
of all nozzles is all canceled.
66020a Nozzle Skip Nozzle Change Error.(Cam lock action)
66020b Nozzle Skip Nozzle Change Error.(Cam Free action)
66020c Nozzle Skip Cam Origin Error.
66020d Nozzle Skip Nozzle Teach Error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0307-004 2-149 AGS01ETRP

3.3 Error IDs and Remedial Procedures
Error ID ltem Description
660301 Head Skip Communication Error
660302 Head Skip Head Origin
660303 Head Skip Overtime Head Origin Return
660304 Head Skip Unselected Nozzle Drop
660305 Head Skip Dummy Nozzle
660306 Head Skip Manual Bypass
660307 Head Skip Alarm Error.
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
660401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
660402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
660403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
660404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
660501 Master Head Offset Linear Measure System Was At High Position.
660502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
0307-005 2-150 AGS01ETRP

3.3 Error IDs and Remedial Procedures
Error ID ltem Description
660601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
660701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
660702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
660801 Recog. Data Teach Recognition Error Code.
660901 Trash Teach Trash Teach Error Code.
Note: Refer to "4. Troubleshooting on Recognition System" for details.