4.3 Recognition Error IDs and Remedial Procedures Recognition Error ID Item Description 02**2301** Error in Electrode (Ball) Inspection The Electrode(ball) position is incorrect. 02**2302** Error in Electrode (Ball) Insp…

4.3 Recognition Error IDs and Remedial Procedures
Recognition Error ID
Item Description
02**2201** Error in Lead Inspection The number of leads is incorrect.
02**2202** Error in Lead Inspection The number of leads is small.
02**2203** Error in Lead Inspection The number of leads is large.
02**2204** Error in Lead Inspection The lead width is incorrect.
02**2205** Error in Lead Inspection The lead width is shorter than the tolerance.
02**2206** Error in Lead Inspection The lead width is longer than the tolerance.
02**2207** Error in Lead Inspection The lead length is incorrect.
02**2208** Error in Lead Inspection The lead length is shorter than the tolerance.
02**2209** Error in Lead Inspection The lead length is longer than the tolerance.
02**2210** Error in Lead Inspection The lead pitch is incorrect.
02**2211** Error in Lead Inspection The lead pitch is smaller than the tolerance.
02**2212** Error in Lead Inspection The lead pitch is larger than the tolerance.
02**2213** Error in Lead Inspection The lead position (LATL DIR) is incorrect.
02**2214** Error in Lead Inspection The lead position (LONG DIR) is incorrect.
(Cause 1) The results of the lead inspection differ from the parameters specified in the
component library data for the selected components.
(Remedy 1) Check the leads of the selected component and the component library
data.
Correct wrong parameters if they are set in the component library data.
0307-004 2-188 AGS01ETRP

4.3 Recognition Error IDs and Remedial Procedures
Recognition Error ID
Item Description
02**2301** Error in Electrode (Ball) Inspection The Electrode(ball) position is incorrect.
02**2302** Error in Electrode (Ball) Inspection There is Electrode(ball) of the size outside per-
missible value.
(Cause 1) There is a difference between the results of the electrode (ball) inspection
of the selected component and the component library data.
(Remedy 1) Check the electrodes (balls) of the selected component and the compo-
nent library data.
Correct wrong parameters if they are set in the component library
data.
02**2401** Error in Polarity Detection. Failed in Polarity Detection.
02**2402** Error in Polarity Detection. The detected polarity differs from specification.
(Cause 1) There is a difference between the results of the polarity determination of the
selected component and the component library data.
(Remedy 1) Check the polarity of the selected component and the component library
data.
Correct wrong parameters if they are set in the component library
data.
02**2901** Picked Posture Error The pick angular skew is big.
02**2902** Picked Posture Error The pick-up position has deviated greatly in X di-
rection.
02**2903** Picked Posture Error The pick-up position has deviated greatly in Y di-
rection.
02**2904** Picked Posture Error The pick-up position has deviated greately in X or
Y direction.
(Cause 1) When a component is picked up, the pick-up positions (X and Y) and angle
have shifted greatly from the correct ones.
(Cause 2) When the tape is fed, a component is turned vertically.
(Remedy 1) Check the selected component and the tape feeder.
Check if the feeder (B) offset data is correct.
Check if the component library data is correct.
(Remedy 2) Check the selected component and the tape feeder.
0307-005 2-189 AGS01ETRP

Recognition Error ID Item Description
02**3101** Error in Corner Detection More than two corners of a component are hid-
den by the protruded nozzle.
02**3102** Error in Corner Detection Corner Not Detected.
(Cause 1) The pick-up position has shifted from the specified one in the X direction.
Fig. 4B21
(Cause 2) The tapered part of the vacuum nozzle end or the diffusion plate is stained.
Fig. 4B22
(Remedy 1) Check the component and the tape feeder.
(Remedy 2) Clean the vacuum nozzle end or the diffusion plate.
02**3201** Error in Center of Gravity Detection The component shape (size) is not applicable.
02**3202** Error in Center of Gravity Detection Failed in Corner Detection.
02**3203** Error in Center of Gravity Detection Failed in Center of Gravity Detection.
(Cause 1) The selected component does not match the nozzle.
(Cause 2) The component is bent due to weak vacuum suction forc
(Remedy 1) Check the selected component and the vacuum nozzle.
(Remedy 2) Check the vacuum pressure.
Component
Vacuum Nozzle
Dirty Spots
4.3 Recognition Error IDs and Remedial Procedures
0307-005 2-190 AGS01ETRP