2.1.2 Pneumatic tubes and wires
The pneumatic tubes and wires of the stopper unit will be installed in the cable duct. The lifting
table, the covers of the cable duct and the cover of the conversion board. 2
: Remove the lifting table.
: Remove the covers of the cable duct.
: Remove the cover of the conversion board.
2
The sensor and the stopper unit have to be connected with the cable from the conversion board.
It is not possible to connect it vice versa, because the connectors don’t fit through the cable duct.2
2
2
2
2
2
2
2
2
2
2
2
Cable
duct
Pneumatic
hoses and
sensor cables
LBO 50 mm SIPLACE D4 2 Assembly instructions SOKO Stopper LBO for minimum board size 50 mm SIPLACE D4
11/2007 Edition
39
: Connect the pneumatic tube with the central air supply in the area between both placement
areas.
2
: Connect the adapter cable xxxxx to X35 at the conversion board.
2
Connection to the central air supply
X 35
2 Assembly instructions SOKO Stopper LBO for minimum board size 50 mm SIPLACE D4 LBO 50 mm SIPLACE D4
11/2007 Edition
40
: Store the plug and socket connection from the adapter cable to the sensors and the stopper
unit in the cable duct near the conversion board.
2
: Guide the wiring from the stopper unit and the supersonic sensor in a loop in horizontal direc-
tion (no contact to movable parts of the conveying system) and store ot together with the cable
from the sensor "stopper position" in the cable duct.
2
2
: Guide the cable from the sensor "stopper position" underneath the Festo drum and link it toge-
ther with the pneumatic tubes.
2
2
2
2
Cable layout to
supersonic sensor
Signal cable "Bero
stopper position"
Guidance of cable