00193351-06_RI_Vacuum_pump_de en.pdf - 第36页
2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 07/2011 Edition 34 2.3.4 SIPLACE HS-50 : Insert the newly installed PUN8-h ose in the adapter PUN8 / PUN4. 2 2 : Loosen the vacuum ho…

SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 2 Retrofit instructions for vacuum pump
07/2011 Edition
33
: Open the two middle screws of the trailing cable.
2
2
: Remove the cover of the gantry distributor (3 screws).
2
2
2
2
2
2

2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series
07/2011 Edition
34
2.3.4 SIPLACE HS-50
: Insert the newly installed PUN8-hose in the adapter PUN8 / PUN4.
2
2
: Loosen the vacuum hose PUN4 of the gantry distributor block and insert the hose in the adap-
ter PUN8/PUN4.
: Install the cover of the trailing cable.
: Install the gantry cover and the rejection bin.
2
Changes on the placement head 2
: Remove the head board.
: Remove the hoses from the vacuum generator.
: Remove the vacuum generator.
: Install the vacuum generator for the vacuum pump (item no. 00307848-01).
: Connect the hoses to the new vacuum generator.
: Remove the Y-joint of hoses no. 5 and no. 2.
PUN8/PUN4
adapter
Newly installed
compressed air hose
Vacuum hoses
Gantry distributor block

SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 2 Retrofit instructions for vacuum pump
07/2011 Edition
35
: Use hose no.1 for compressed air.
The remaining hoses are for vacuum.
: Mount the head board.
2
2
2
2
2
2
New vacuum generator
1x compressed air
6x vacuum