2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 07/2011 Edition 40 : Close the second port in every stopcock with a blind plug. 2 Drilling the ne cessary holes for vacuum distributo…

100%1 / 60
SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 2 Retrofit instructions for vacuum pump
07/2011 Edition
39
2.4 Retrofitting instructions for vacuum pump on
S-25 HM / S-27 HM
2.4.1 Required parts
Connection kit for vacuum pump S-25 HM (item number 00118300-01) 2
Connection kit for vacuum pump S-27 HM (item number 00118506-01) 2
Vacuum pump (item no. 00119794-xx) 2
2.4.2 Required tools
Set of allen keys 2
Set of flat wrenches 2
Cross-head screwdriver 2
2.4.3 Fitting
: Switch the placement machine off at the main switch and disconnect it from the power supply.
: Open the compressed air supply door.
: Close the main compressed air stopcock.
: Close the stopcock.
: Remove the comprssed air hoses at both stopcocks (4 hoses).
: Connect the 4 compressed air hoses to the vacuum distributor.
: Connect a new compressed air hose to every stopcock.
2
2
2
2
2
2
2
2
2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series
07/2011 Edition
40
: Close the second port in every stopcock with a blind plug.
2
Drilling the necessary holes for vacuum distributor 2
: Pull the power supply out of the placement machine.
: Drill two holes (diameter 4,9 mm), cut two threads M6 into the holes.
2
Vacuum distributor 3/4’
Plug for
vacuum hose
Blind plug
(necessary)
Remove angle shackle
(only S-27 HM))
Compressed air hoses
from stopcocks
40 mm
60 mm
40 mm
SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 2 Retrofit instructions for vacuum pump
07/2011 Edition
41
: Mount the vacuum generator with the two Allan screws M6.
2
2
: Remount the power supply.
2
1
2
5
3
4
6 (new)
Compressed air distributor
Compressed air distributor
Placement head 1
1
2
New distributor block New distributor block
7
7
Placement head 2
PUN 3 blind plugs
Pneumatics