2 Replacing spare parts 2.6 Contact module Service Manual SIPLACE MeasurementFeeder X 02/2020 23 ► Connect the contact module to the connector. ► Put a drop of Loctite 243 on the two marked screws (M3X12 Allen screw, 030…

2 Replacing spare parts
2.6 Contact module
22 Service Manual SIPLACE MeasurementFeeder X 02/2020
► Disconnect the connector form the contact mod-
ule.
► To remove the contact module from the measure-
ment feeder, push contact module in direction of
arrow.
2.6.2 Fitting the contact module
► Insert the contact module back to the Measure-
mentFeeder.

2 Replacing spare parts
2.6 Contact module
Service Manual SIPLACE MeasurementFeeder X 02/2020 23
► Connect the contact module to the connector.
► Put a drop of Loctite 243 on the two marked
screws (M3X12 Allen screw, 03042544).
► Tighten the two screws on the top of the contact
module.
► Align the protective plate.
► Tighten the four cross head countersunk screws
(ISO7046-2 M2.5X6, 03023228-xx) to hold the
protective plate.
Put the contact module cover on the top of the contact
module as shown.
► Tighten the two cross head countersunk screws
(ISO7046-2 M3X6, 03023238-xx) to hold the con-
tact module cover.

2 Replacing spare parts
2.7 Measurement board
24 Service Manual SIPLACE MeasurementFeeder X 02/2020
2.7 Measurement board
Required spare part
Fig.6: Measurement board cpl
Feeder module Item no. Designation
MeasurementFeeder X 03210586-xx Measurement board cpl
Required tools
●
Flat-bladed screwdriver
●
Phillips screwdriver
●
Spanner, size 5mm
●
Loctite 243