00193732-02.pdf - 第49页

SIPLACE HS-50/HS-60 2 Retrofit Instructions for PCB Camera Mult icolor, HS-50 / HS-60 11/2004 Edition 2.4 Retrofit Kits, Tools 49 2.4 Retrofit Kit s, T ools 2.4.1 Re trofit Kit "PCB Camera Multicolor HS-50 / HS-60&q…

100%1 / 86
2 Retrofit Instructions for PCB Camera Multicolor, HS-50 / HS-60 SIPLACE HS-50/HS-60
2.3 Safety Instructions 11/2004 Edition
48
Rules for Germany:
Observe the guidelines of the Main Association of the German Trade Association, VBG 93.
In all other countries, comply with the pertinent guidelines and standards of the specific countries
in question.
Standards to be observed:
IEC 60825-1, EN 60825-1.
2
2.3.2 Definitions
DANGER
In terms of these instructions means that death, severe bodily injury or considerable material da-
mage WILL occur if the instructions about danger are not followed.
2
CAUTION
in terms of these instructions mean that minor bodily injury or material may occur if the cautions
are not heeded. 2
2
2
2
2
2
2
2
2
2
2
2
SIPLACE HS-50/HS-60 2 Retrofit Instructions for PCB Camera Multicolor, HS-50 / HS-60
11/2004 Edition 2.4 Retrofit Kits, Tools
49
2.4 Retrofit Kits, Tools
2.4.1 Retrofit Kit "PCB Camera Multicolor HS-50 / HS-60"
2
2.4.2 Tools, Auxiliary Test Equipment and Expendable Materials
Set of Allen wrenches
Oblique-nosed cutting pliers
Open-end wrench or size 6 mm socket wrench
Wire stripper
ESD bracelet
Crimping pliers made by AMP (for connector sleeves)
Insulating tape and permanent marker
Ethyl alcohol.
1 Retrofit kit "PCB camera Multicolor HS 50 / HS-60" Item no: 00358031-01
4 PCB camera Multicolor assembly made by Sticksel each with 2 con-
nection cables
Item no: 00355462-01
4 Distance plate (= spacer) Item no: 00348078-01
12 hex head cap screw M3 x 14 (captive) Item no: 00327105-01
4 PC camera board, modular, made by Sticksel Item no: 00344490-01
12 Spacer bolts, PCB camera, L = 8.5 mm Item no: 03000189-01
4 Retrofit kit for PCB camera HS-50, main distribution frame consisting of: Item no: 00357512-01
1 Converter 24V/50V (universal illumination converter) Item no: 00349095-01
1 Relay RS 30 / 24 VDC GSE 1 A, Order no. 110166 Item no: 00345646-01
2
Feed-through terminal, gray, 3-wire Item no: 00336767-01
1
Closing plate 2.5 mm, orange, 3-wire Item no: 00336771-01
1
Transverse link (gray), 3-wire Item no: 00336773-01
1
End clip with no screws Item no: 00353373-01
1 cable W1, W2, W3, W4, W5
4 Twin connector sleeve, grey, 4 x 0,75 mm
2,
manufacturer: Bürklin
Order no: 18H 7081
4 Distance bolts (length: 5 mm, thread M3)
2 Retrofit Instructions for PCB Camera Multicolor, HS-50 / HS-60 SIPLACE HS-50/HS-60
2.5 Preparatory Steps 11/2004 Edition
50
2.5 Preparatory Steps
: Open the safety hoods.
: Remove the reject bin.
: Disassemble the head crash protections.
: Undock the movable component changeover tables.
: Turn the machine off at the main switch, isolate the machine from the mains, turn off the flow
of compressed air at the compressed air unit.
: Push the X-gantries toward the outside of the machine so that the placement heads are readily
accessible.
2.6 Changeover at Main Distribution Frame
: Open the machine frame door and the safety hood at feeder location 4, to the left of the input
station.
: Undo the 3 socket hex head cap screws on top of the side panel (just loosen the 3 screws on
the bottom).
: Lift the side panel of the machine frame straight up out of the slots.
: Set it on the side of the machine so that the main distribution frame is readily accessible.
Do not damage the grounding cable.
Undo screws
Loosen screws