wire-bonder.pdf - 第63页

WEST•BOND MODEL 454647E SER IES INSTRUCTION MANUAL 57 ADVANCED PROGRAMMING Ball Fault F OR 4700E M ODE O NLY When the B ALL F AULT D ETECTION is turned on, the m achine will detect a short or open condition in relation t…

100%1 / 126
WEST•BOND MODEL 454647E SERIES INSTRUCTION MANUAL
56
ADVANCED PROGRAMMING
Wire Tail
This option allows the operator to increase or decease the length of the tail: meaning the wire length
offered for view prior to performing the first bond. The suggested settings of 24 steps for 45° (4500E), 35
steps for 90° (4600E), and 60 steps for 90° ball (4700E) applications are displayed on the menu. The
numerical selection defines the number of motor steps. To increase the tail length, increase the tail
number. To change the selected number, use the “4” key to key data, or the “5” key to increase, or the “0”
key to decrease.
WIRE TAIL (See ϑ below or G was pressed from Edit Wire Pull Menu)
Wire Tail: 24 steps
4=Key in 5=Increase
8=Suggest
A=Prev option 0=Decrease G=Next option
60 steps is the suggested setting for 4700E
Program in A motor half-steps.
8 = Restore after suggestion is made.
ϑ To edit “Wire Tail”
F
OR 4500E AND 4600E MODES ONLY
From the H
OME menu press 4 (EDIT), 6 (MACHINE), and then 6 (WIRE TAIL)
ϑ To edit “Wire Tail”
F
OR 4700E MODE ONLY
From the H
OME menu press 4 (EDIT), 6 (MACHINE), and then 5 (WIRE TAIL)
Key Format:
Previous
Menu
1
2
Home
3
Key in
4
Increase
5
6
7
Suggest
8
9
Previous
option
A
Decrease
0
Next option
G
WEST•BOND MODEL 454647E SERIES INSTRUCTION MANUAL
57
ADVANCED PROGRAMMING
Ball Fault
FOR 4700E MODE ONLY
When the B
ALL FAULT DETECTION is turned on, the machine will detect a short or open condition in relation
to the torch wand and the gold wire. The factory suggests that the BALL FAULT DETECTION setting be left
on.
Ball Fault Detection: On
5=On
8=Suggest
A=Prev option 0=Off G=Next option
ϑ To edit “Ball Fault”
From the H
OME menu press 4 (EDIT), 6 (MACHINE), and then 6 (BALL FAULT)
Key Format:
Previous
Menu
1
2
Home
3
4
On
5
6
7
Suggest
8
9
Previous
option
A
Off
0
Next option
G
WEST•BOND MODEL 454647E SERIES INSTRUCTION MANUAL
58
ADVANCED PROGRAMMING
Dual Force
This option allows the operator to select whether the “Dual Force” feature is “ON” or “OFF”. When the
“OFF” selection is made, the “Low Force Calibration” menu will not be displayed and the higher specified
force will be applied to all wire bonds. To change the setting of this option simply press the “0” key for
“OFF” or the “5” key for “ON”. If this feature is selected to the “ON” position, the low force will be
suggested for the first bond and the high force will be suggested for the consecutive bonds. These are
suggestions only. Thus low force or high force may be specified for any bond in any order. See page 82
for details on how to select High or Low force for each individual bond.
N
OTE! The Dual Force factory setting is “OFF” in the 4500E and the 4600E modes. In
the 4700E mode, “Dual Force” is “ON” and set up for 20 grams of difference.
DUAL FORCE (See ϑ below or G was pressed from Edit Wire Tail Menu).
Dual Force: Off
5=On
8=Suggest
A=Prev option 0=Off G=Next option
8 = Restore after suggestion is made.
ϑ To edit “Dual Force”
From the H
OME menu press 4 (EDIT), 6 (MACHINE), and then 7 (DUAL FORCE)
Key Format:
Previous
Menu
1
2
Home
3
4
On
5
6
7
Suggest
8
9
Previous
option
A
Off
0
Next option
G