3.1.9 LED Assignment on the Subdistributor Electrics and Control
Service Manual SIPLACE X Series 69
3.1.9
3.1.9 LED Assignment on the Subdistributor
LED Assignment on the Subdistributor
3.1.9.1
3.1.9.1 I/O Module, Subdistributor (Inputs) [old: 03010005-05]
I/O Module, Subdistributor (Inputs) [old: 03010005-05]
nc = not connected (reserve)
1. LEDs Do 0 to Do 15 (digital outputs)
2. LEDs Di 0 to Di 23 (digital inputs)
3. Subdistributor
4. 1 wire RS232 bridge (plugged in)
5. DIP switch
Remove the cover on the subdistributor (3) in
sector 4.
The table below shows the LED assignment. If the
position is active, the LED will shine.
Terminals I / O Description / Note
X3_1 Di0 M_NotAusSchleife1ok or M_Security Loop ("high" if all safety loops are
closed (protective hoods, emergency STOP buttons, component flaps,
changeover tables).
X3_2 Di1 M_D0ServoAdressBus Bit-0 of servo address!
Each servo assembly is assigned an ID number (0-16). This number can
be reconstructed from all 4 servo address bus messages. With the help
of the EA2/Do0 to EA2/Do4 outputs, each servo card can be addressed
in the intended slot.
X3_3 Di2 M_D1ServoAdressBus Bit-1 of servo address!
X3_4 Di3 M_D2ServoAdressBus Bit-2 of servo address!
X3_5 Di4 M_D3ServoAdressBus Bit of servo address!
X3_6 Di5 M_Drucksensor Hauptventil/ "high" signal when compressed air level is
reached
X3_7 Di6 M_Vakuumpumpe EIN
X3_8 Di7 nc
X4_1 Di8 M_StartTaste "high" signal while the start button is pressed. The function
of this button triggers the protective contactor combination, all axes are
ready for operation.
X4_2 Di9 M_StopTaste"high" signal while the stop button is pressed. .
X4_3 Di10 M_Abwurfbehälter
X4_4 Di11 M_ PortalCrash2 "low" signal gantries 1 and 4 too close,"high" signal is
normal operating status
X4_5 Di12 nc
X4_6 Di13 M_ ServoEnable2 or Steuerung Ein/"high" signal intermediate circuit volt-
age for X/Y servo on axis unit 2 - switched through. (K4 message)
X4_7 Di14 nc
Service Work
Electrics and Control 3.1.9 LED Assignment on the Subdistributor
70 Service Manual SIPLACE X Series
3.1.9.2
3.1.9.2 I/O Module, Subdistributor (Inputs) [new: 03046226-01]
I/O Module, Subdistributor (Inputs) [new: 03046226-01]
nc = not connected (reserve)
X4_8 Di15 M_ NotAusTasteMTC/"high" signal - emergency STOP button activated.
X5_1 Di16 nc
X5_2 Di17 M_ Haube1 "high" signal if cover 1 is closed.
X5_3 Di18 M_ BE-Tisch1 "high" signal if changeover table 1 is docked.
X5_4 Di19 M_ HaubeLP-Eingabe "high" signal if the cover above the PCB input is
closed.
X5_5 Di20 M_ NotAusTasteLP-Eingabe "high" signal if the emergency STOP button
is unlocked.
X5_6 Di21 M_ Haube4 "high" signal if cover 4 is closed.
X5_7 Di22 M_BE-Tisch4 "high" signal if changeover table 4 is docked.
X5_8 Di23 nc
X6_1 5 V
X6_2 GND
X6_3 GND
X6_4 GND
X6_5 nc
X6_6 nc
X6_7 nc
X6_8 nc
Terminals I / O Description / Note
Terminals I / O Description / Note
X3_1 Di0 M_NotAusSchleife1ok or M_Security Loop ("high" if all safety loops are
closed (protective hoods, emergency STOP buttons, component flaps,
changeover tables).
X3_2 Di1 nc
X3_3 Di2 nc
X3_4 Di3 nc
X3_5 Di4 nc
X3_6 Di5 M_Drucksensor Hauptventil/ "high" signal when compressed air level is
reached
X3_7 Di6 M_Vakuumpumpe EIN
X3_8 Di7 nc
X4_1 Di8 M_StartTaste "high" signal while the start button is pressed. The function
of this button triggers the protective contactor combination, all axes are
ready for operation.
X4_2 Di9 M_StopTaste"high" signal while the stop button is pressed. .
X4_3 Di10 nc
X4_4 Di11 M_ PortalCrash2 "low" signal gantries 1 and 4 too close,"high" signal is
normal operating status
X4_5 Di12 nc
X4_6 Di13 M_ ServoEnable2 or Steuerung Ein/"high" signal intermediate circuit volt-
age for X/Y servo on axis unit 2 - switched through. (K4 message)
X4_7 Di14 nc
Service Work
3.1.9 LED Assignment on the Subdistributor Electrics and Control
Service Manual SIPLACE X Series 71
3.1.9.3
3.1.9.3 I/O Module for Subdistributor (Outputs) (old)
I/O Module for Subdistributor (Outputs) (old)
nc = not connected (reserve)
X4_8 Di15 M_ NotAusTasteMTC/"high" signal - emergency STOP button activated.
X5_1 Di16 nc
X5_2 Di17 M_ Haube1 "high" signal if cover 1 is closed.
X5_3 Di18 M_ BE-Tisch1 "high" signal if changeover table 1 is docked.
X5_4 Di19 M_ HaubeLP-Eingabe "high" signal if the cover above the PCB input is
closed.
X5_5 Di20 M_ NotAusTasteLP-Eingabe "high" signal if the emergency STOP button
is unlocked.
X5_6 Di21 M_ Haube4 "high" signal if cover 4 is closed.
X5_7 Di22 M_BE-Tisch4 "high" signal if changeover table 4 is docked.
X5_8 Di23 nc
X5_8 Di23 nc
X6_1 nc
X6_2 nc
X6_3 GND
X6_4 nc
X6_5 nc
X6_6 nc
X6_7 nc
X6_8 nc
Terminals I / O Description / Note
Terminals I / O Description / Note
X7_1 Do0 St_D0ServoSlot Bit-0 of servo slot ID! Each servo assembly is assigned
an ID number (0-16). This number can be reconstructed from all 4 servo
address bus messages. With the help of the EA2/Do0 to EA2/Do4 out-
puts, each slot intended for servo cards can be addressed.
X7_2 Do1 St_D1ServoSlot/Bit-1 of servo slot ID!
X7_3 Do2 St_D2ServoSlot/Bit-2 of servo slot ID!
X7_4 Do3 St_D3ServoSlot/Bit-3 of servo slot ID!
X7_5 Do4 St_D4ServoSlot/Bit-4 of servo slot ID!
X7_6 Do5 St_DruckluftHauptventil/A "low" signal opens the valve
X7_7 Do6 nc
X7_8 Do7 nc
X8_1 Do8 nc
X8_2 Do9 nc
X8_3 Do10 nc
X8_4 Do11 nc
X8_5 Do12
X8_6 Do13
X8_7 Do14
X8_8 Do15
X9_1 24 V