00194610-01.pdf - 第18页

Retrofit instructions: Modification of the nozzle changer power supply for the DLM placement heads, HF series 07/2005 Edition 18 2 2 2 2 2.2.1 T ools and consumables required Set of screwdrive rs 2 Set of hexa gon socket…

100%1 / 30
Retrofit instructions: Modification of the nozzle changer power supply for the DLM placement heads, HF series
07/2005 Edition
17
2 Retrofit instructions: Modification of
the nozzle changer power supply for
the DLM placement heads, HF series
2.1 Description of the functions
The conversion only has to be carried out at the locations at which the C&P placement head, noz-
zle changer and one-wire hub are installed. 2
2.2 Parts required
2
2
2
2
2
2
Cable for retrofit for 1-wire hub
Item no.: 03037890-xx
Supply cable for 1-wire hub
Item no.: 03037882-xx
HF nozzle changer, 12-segment C+P head
Item no.: 00119661-
Basic package: nozzle changer, 12-segment RV HF/X Item no.: 03041752-
Nozzle changer, 12-segment rev. SIPLACE HF
Item no.: 03001855- 1
DIN912-M5 x 12-A2
Item no.: 00315186- 4
Nozzle reject bin, complete
Item no.: 03006022- 1
DIN912-M5 x 16-8.8
Item no.: 00845044- 2
DIN 6325 - 5m5 x 16-St
Item no.: 00619866- 2
Hose connector Y-PK-3
Item no.: 00305382- 1
Air hose PUN4x0.75-600 long
Item no.: 03011731- 1
Retr.Inst. nozzle ch.C+P head, HF series
Item no.: 00193756- 1
Installation kit / 1-wire hub NCH
Item no.: 03025027- 1
Installation kit / 1-wire hub CAT5
Item no.: 03041617- 1
Retrofit instructions: Modification of the nozzle changer power supply for the DLM placement heads, HF series
07/2005 Edition
18
2
2
2
2
2.2.1 Tools and consumables required
Set of screwdrivers 2
Set of hexagon socket spanners 2
Set of TORX drivers 2
HF nozzle changer, 6-segment C+P head
Item no.: 00119662-
Basic package: nozzle changer, 6-segment RV HF/X Item no.: 03041753-
Nozzle changer, 6-seg. turned, SIPLACE HF
Item no.: 03004010- 1
DIN912-M5 x 12-A2
Item no.: 00315186- 4
Nozzle reject bin, complete
Item no.: 03006022- 1
DIN912-M5 x 16-8.8
Item no.: 00845044- 2
DIN 6325 - 5m5 x 16-St
Item no.: 00619866- 2
Hose connector Y-PK-3
Item no.: 00305382- 1
Air hose PUN4x0.75-600 long
Item no.: 03011731- 1
Retr.Inst. nozzle ch.C+P head, HF series
Item no.: 00193756- 1
Installation kit / 1-wire hub NCH
Item no.: 03025027- 1
Installation kit / 1-wire hub CAT5
Item no.: 03041617- 1
Sensor for component reject bin
Item no.: 00116848-
Reject bin, HF / X series Item no.: 03041754-
Optional parts for reject bin, HF / X series
Item no.: 03021595- 1
Hinged box 145*140*90
Item no.: 00066220- 1
Diaphragm D2551
Item no.: 00066227- 2
Bag, poly / 80*100*0.06mm/transparent
Item no.: 00066017- 2
Mushroom-head self-tapping screw, Torx D2.5x6
Item no.: 03009465- 4
X series cable/HF R2: reject bin
Item no.: 03022078- 1
Retrofit inst. reject bin for HF /X series
Item no.: 00194550- 1
MODULE / NCH 1 wire hub
Item no.: 03020668- 1
Installation kit / 1-wire hub CAT5
Item no.: 03041617- 1
Assembly Instr. Reject bin sensor, X-series / D3 Item no.: 00194716- 1
Retrofit instructions: Modification of the nozzle changer power supply for the DLM placement heads, HF series
07/2005 Edition
19
2.3 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with mains voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the retrofit, always secure the machine to prevent access by other people and to prevent
it being switched on again. The procedure is described in the “Locking the machine…” section of
the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized and trained personnel.
2
2
2
2
2