Retrofit instructions: Modification of the nozzle changer power supply for the DLM placement heads, HF series 07/2005 Edition 24 : Remove the cover from the connector . : Pull the cable through the rear strain relief on …

100%1 / 30
Retrofit instructions: Modification of the nozzle changer power supply for the DLM placement heads, HF series
07/2005 Edition
23
: Run the cable towards the machine frame (see photograph).
: Fix the cable using cable ties.
2
: Thread the cable through the vertical cable duct on the machine frame (see photograph).
: Pull the connector out of the machine frame.
2
Cable duct
Plug
Retrofit instructions: Modification of the nozzle changer power supply for the DLM placement heads, HF series
07/2005 Edition
24
: Remove the cover from the connector.
: Pull the cable through the rear strain relief on the connector.
2
2
: Use a size 0 or smaller screwdriver to open the connector.
Insert the screwdriver as far as it will go (approx. 13 mm) and lever out the bar.
2
2
Strain relief
Retrofit instructions: Modification of the nozzle changer power supply for the DLM placement heads, HF series
07/2005 Edition
25
: Attach the new cable to the connector:
additional white at pin 1,
brown at pin 2.
2
2
: Tighten the screws of the strain relief.
: Fit the cover onto the connector.
: Connect the connector to its counterpart and pack the two connectors into the machine frame.
2
: Carry out this conversion at all the locations at which a C&P placement head with nozzle
changer is installed.
2
2
2
2
2
2
white at pin 1 (additional)