Retrofit instructions: Modification of the nozzle changer power supply for the DLM placement heads, HF series 07/2005 Edition 23 : Run the cable towards the machine frame (see photograph). : Fix the cable using cable tie…

100%1 / 30
Retrofit instructions: Modification of the nozzle changer power supply for the DLM placement heads, HF series
07/2005 Edition
22
: Plug in the distributor cables as follows:
2
2
: Screw the CAN bus connector to the adapter.
2
2
2
2
2
2
2
Connect to one-wire hub
W1: Connect to CAN bus cable
W2: Connect to cable pulled
out towards the machine frame
Connectors
Retrofit instructions: Modification of the nozzle changer power supply for the DLM placement heads, HF series
07/2005 Edition
23
: Run the cable towards the machine frame (see photograph).
: Fix the cable using cable ties.
2
: Thread the cable through the vertical cable duct on the machine frame (see photograph).
: Pull the connector out of the machine frame.
2
Cable duct
Plug
Retrofit instructions: Modification of the nozzle changer power supply for the DLM placement heads, HF series
07/2005 Edition
24
: Remove the cover from the connector.
: Pull the cable through the rear strain relief on the connector.
2
2
: Use a size 0 or smaller screwdriver to open the connector.
Insert the screwdriver as far as it will go (approx. 13 mm) and lever out the bar.
2
2
Strain relief