00191474-02.pdf - 第18页
Cable mounting plate on t he head board Retrof it instructions HS -50 1 1/99 edition 18 2 Safety instructions WAR N IN G This retr ofit mus t only be carrie d out b y SIEME NS enginee rs. 2 Å Always follow the acciden t …

Retrofit instructions HS -50 Cable mounting plate on the head board
11/99 edition
17
1Overview
This manual describes how to retrofit the cable mounting plate (item 1 in Fig.1 - 1) and the
additional Velcro fasteners on HS-50 placement systems. 1
The cable mounting plate and Velcro fasteners are used to fix the cables for the DLM1 head. 1
1
Fig. 1 - 1 HS-50 cable mounting plate
Key to Fig. 1-1
(1) Cable mounting plate
(2) Velcro fastener for the vacuum board ribbon cable
(3) Velcro fastener for the ribbon cable of the incremental encoder for the turning station/DLM1
(4) Round cable holder for the motor cables of the turning station/DLM1
(5) Velcro fastener for the ribbon cable of the ‘Pick up’ positioning unit
(6) Velcro fastener for the ribbon cable of the ‘Discard’ positioning unit

Cable mounting plate on the head board Retrofit instructions HS -50
11/99 edition
18
2 Safety instructions
WARNING
This retrofit must only be carried out by SIEMENS engineers. 2
Å Always follow the accident prevention regulations applicable in your country, e.g. EN 60204.
2
Å End all placement operations on the placement system.
Å Shut down the Windows NT operating system correctly, otherwise problems may occur when
restarting the placement system or data may be lost.
Å Switch the placement system off at the main switch.
Å Disconnect the placement system from the mains power supply.
Å Secure the system to prevent reclosing and put up a sign to indicate that servicing work is
being carried out (see section 2 – Operational safety of the operating instructions).
Å Open the protective covers and move the main gantry into a comfortable working position.
WARNING
To avoid damaging the revolver head, always observe the following points when moving the
gantry. 2
– NEVER move the gantry by pushing against the revolver head with your hands.
– NEVER move the gantry by pushing against the revolver head handle with your hands or by
pulling the handle. The revolver head may lose its settings or be damaged on account of the
high braking force of the y gantry drive.
– NEVER move the gantry while the z axis is lowered.
– Take hold of the cast iron part of the x axis and then move the gantry.
2
Retrofit instructions HS -50 Cable mounting plate on the head board
11/99 edition
19
3 Tools and equipment
– M3 socket spanner
– Set of hexagon socket spanners
– Ethyl alcohol
– Clean, lint-free cloth
– Loctite 243 thread adhesive
4Parts
Cable mounting plate for HS-50 head board, complete, item no. 00347626-02, consisting of: 4
– Cable mounting plate for HS-50 head board, item no. 00346193-02, 1 x (Fig. 1 - 1)
– Velcro fastener, item no. 00346483-01, 14 x (Fig. 1 - 1)
– Round cable mount, 19x15, item no. 00347941-01, 1 x (Fig. 1 - 1)
Velcro fastener, item no. 00346483-01, 8 x (Fig. 6 - 1) 4
Round cable mount, 19x15, item no. 00347941-01, 1 x (Fig. 6 - 1) 4
Fixing parts, item no. 00348077-01, set, consisting of (Fig. 7 - 1) 4
– Position I
M3x5 fillister head screw, DIN 912, item 7
2x M3x18 spacer bolts (internal thread, external thread), item 9
M3 washer, DIN 433, item 4
M3 nut, DIN 934, item 5
– Position II
M3x20 fillister head screw, DIN 912, item 8
Spacer sleeve, Ø 3.2x6x4, item 10
M3 washer, DIN 9021, item 13
M3x5 spacer bolt, (internal thread, internal thread), item 14
M3x15 spacer bolt, (internal thread, internal thread), item 16
M3 washer, DIN 433, item 4
M3x5 fillister head screw, DIN 912, item 6
– Position III
M3x5 fillister head screw, DIN 912, item 7
2x M3x18 spacer bolts (internal thread, external thread), item 9
M3 washer, DIN 433, item 4
M3 nut, DIN 934, item 5