Retrofit Instructions Oblique Lighting for SIPLACE 80 S-20 /F4/S-23/ F5 /HS-50/HF 8.3 Installing the Oblique Lighting 05/15 Issue 28 8 Fig. 8.3.8 S23: Connection of the Cable ► S23: Plug the 2-pin connector (1 in Fig. 8.…

100%1 / 34
Oblique Lighting for SIPLACE 80 S-20 /F4/S-23/ F5 /HS-50/HF Retrofit Instructions
05/15 Issue 8.3 Installing the Oblique Lighting
27
HS50: Fasten the 2 cables to the existing camera cables and run them upward to the head
PCB.
8
Fig. 8.3.7 Laying Cable Upward
DANGER to eyesight 8
Invisible LED radiation.
Do not look directly into the beam, not even with optical instruments. Damage to or loss of eye-
sight may result.
LED Radiation Class 3b and 2 as per EN 60825-1:94.
8
S23/HS50: Lay the 2 cables (1+2 in Fig. 8.3.7) upward as shown and also fasten them in place
with cable clamps (3 in Fig. 8.3.7).
Retrofit Instructions Oblique Lighting for SIPLACE 80 S-20 /F4/S-23/ F5 /HS-50/HF
8.3 Installing the Oblique Lighting 05/15 Issue
28
8
Fig. 8.3.8 S23: Connection of the Cable
S23: Plug the 2-pin connector (1 in Fig. 8.3.8) onto the 2 pins X5 of the head PCB. Make certain
that the bottom cable is red.
8
Fig. 8.3.9 Fastening the 2 Cables in Place
S23/HS50: Run back the end of the 9-pin cable for the oblique lighting (2 in Fig. 8.3.9) (this 8-
pin cable is not needed).
HS50: Fasten the 9-pin cable for the standard lighting as well.
1
1
2
Oblique Lighting for SIPLACE 80 S-20 /F4/S-23/ F5 /HS-50/HF Retrofit Instructions
05/15 Issue 8.3 Installing the Oblique Lighting
29
S23/HS50: Fasten the 2 cables to the cable harness with additional cable ties (see Fig. 8.3.9).
S23/HS50: Screw the cover back on the placement head.
Note: You will find additional information regarding HS-50 in Section 5. 8
HF: Plug the 2-pin connector onto the X6 plug of the vision board (see Fig. 8.3.10).
8