Retrofit Instructions Oblique Lighting for SIPLACE 80 S-20 /F4/S-23/ F5 /HS-50/HF 8.5 Moving In the Component Changeover Table 05/15 Issue 32 ► Exit the editing box and exit the settings box with "Accept". ► Re…

100%1 / 34
Oblique Lighting for SIPLACE 80 S-20 /F4/S-23/ F5 /HS-50/HF Retrofit Instructions
05/15 Issue 8.5 Moving In the Component Changeover Table
31
9Software
9
Fig. 9.0.1 Menu: "Configure the Machine"
At the station computer, select "Settings" in the SITEST program and then "Machine configu-
ration".
9
Fig. 9.0.2 SITEST Program Menu: "Basic View of Machine"
Mark "Ceramic substrate centering" with a double click and then mark the option "Additional
PCB camera lighting" in the editing box.
9
Fig. 9.0.3 Menu: "Ceramic Substrate Centering"
Retrofit Instructions Oblique Lighting for SIPLACE 80 S-20 /F4/S-23/ F5 /HS-50/HF
8.5 Moving In the Component Changeover Table 05/15 Issue
32
Exit the editing box and exit the settings box with "Accept".
Reboot the station computer (the reconfiguration does not take effect until this has been done).
The oblique lighting will then be ready to use. 9
Oblique Lighting for SIPLACE 80 S-20 /F4/S-23/ F5 /HS-50/HF Retrofit Instructions
05/15 Issue 8.5 Moving In the Component Changeover Table
33
10 HS-50
To activate "oblique lighting blue", you must proceed as follows: 10
Unplug the 8-pin connector (1 in Fig. 10.0.1 and 10.0.2) of the standard lighting.
10
Fig. 10.0.1 S50: 8-Pin Connector of the Standard Lighting
1
2