00192211-02_RI_ObliqueLighting.pdf - 第29页

Oblique Lighting for SIPLACE 80 S-20 /F4/S-23/ F5 /HS-50/HF Retrofit Instructions 05/15 Issue 8.5 Moving In the Component Changeover Table 31 9S o f t w a r e 9 Fig. 9.0.1 Menu: "Configur e the Machine" ► At th…

100%1 / 34
Retrofit Instructions Oblique Lighting for SIPLACE 80 S-20 /F4/S-23/ F5 /HS-50/HF
8.4 Moving In the Movable Component Changeover Table 05/15 Issue
30
8.4 Moving In the Movable Component Changeover
Table
(Note: You will find detailed instructions in the User Manual for the placement machine.) 8
Push the movable component changeover table back into the placement machine somewhat
and connect the 2 cables and the compressed air hose.
Turn the placement machine ON at the main switch.
Lift the movable component changeover table and push it all the way in.
Lift it completely one more time and then let it sink onto the centering pin (and fasten it in
place).
Close the safety hood.
8.5 Moving In the Component Changeover Table
Make certain that the contact surfaces of the component changeover table and the machine
are clean.
Use the pallet jack to pick up a component changeover table and then lift the table until it will
not hang up anywhere when it is pushed into the machine.
Carefully push the component changeover table into the machine until the component change-
over table centering pin location holes are over the centering pins.
Carefully lower the component changeover table until the it is resting on the receiver of the ma-
chine frame.
Close the tension lever.
Next, plug in the flat connector for the communication signals.
Insert the 2 socket hex head cap screws and tighten them.
Plug in the round connector for the power. Close the safety hoods.
Oblique Lighting for SIPLACE 80 S-20 /F4/S-23/ F5 /HS-50/HF Retrofit Instructions
05/15 Issue 8.5 Moving In the Component Changeover Table
31
9Software
9
Fig. 9.0.1 Menu: "Configure the Machine"
At the station computer, select "Settings" in the SITEST program and then "Machine configu-
ration".
9
Fig. 9.0.2 SITEST Program Menu: "Basic View of Machine"
Mark "Ceramic substrate centering" with a double click and then mark the option "Additional
PCB camera lighting" in the editing box.
9
Fig. 9.0.3 Menu: "Ceramic Substrate Centering"
Retrofit Instructions Oblique Lighting for SIPLACE 80 S-20 /F4/S-23/ F5 /HS-50/HF
8.5 Moving In the Component Changeover Table 05/15 Issue
32
Exit the editing box and exit the settings box with "Accept".
Reboot the station computer (the reconfiguration does not take effect until this has been done).
The oblique lighting will then be ready to use. 9