Installation Manual, Station Software Version 602.01 Edition 06/2006
54 of 60
Phoenix FirstBIOS(tm) Desktop CMOS Setup Utility
PnP/PCI Configurations
===================================================================
PNP OS Installed [No]
Reset Configuration Data [Disabled]
Resources Controlled by [Auto(ESCD)]
x IRQ Resources Press Enter
x IMA Resources Press Enter
PCI/VGA Palette Snoop [Disabled]
Assign IRQ for USB [Disabled]
→ Save the BIOS settings and exit the BIOS Setup.
4.8.1.6 Restore initial configuration
→ Remove RMOS installation CD from the USB CD drive.
→ Remove the keyboard from the machine controller and connect it to the station computer.
→ Switch video multiplexer to SR1.
→ Disconnect the USB cable from the USB CD drive and the machine controller.
→ Press <Ctrl><Alt><Del> to warm start the machine controller.
4.8.2 BIOS update and settings
The current BIOS version and the required BIOS settings are supplied as ISO images on the installation
CD. These images can be used to create bootable CDs with suitable CD writing software on a PC with a
CD writer. These CDs can in turn be used to automatically update the BIOS and make the BIOS settings.
Procedure:
→ Create the CD 'CPU086_MC_BIOS_Update'.
→ Create the CD 'CPU086_MC_BIOS_Settings'.
→ Remove the keyboard from the station computer and connect it to the machine controller.
→ Switch the video multiplexer to SR2/MC.
→ Insert the CD 'CPU086_MC_BIOS_Update' in the USB CD drive and connect the drive to the machine
controller using a USB cable.
→ Press <Ctrl><Alt><Del> to warm start the machine controller.
→ During the warm start, press <Del>.
→ Set the BIOS so that the system boots from the USB CD drive (see section
4.8.1.3).
→ Reboot the machine controller and follow the BIOS update instructions.
→ Insert the CD 'CPU086_MC_BIOS_Settings'.
→ Reboot the machine controller and follow the BIOS setting instructions.
→ Reboot the machine controller and deactivate the USB interface again (see section
4.8.1.5).
→ Restore the initial configuration (see section 4.8.1.6).
Installation Manual, Station Software Version 602.01 Edition 06/2006
55 of 60
4.8.3 Manual installation of the machine controller software
The following step can be omitted if the station software is installed. (The MC Distributor is called during the
course of the station software installation.)
→ Open the Start menu and select Programs Æ Siplace Æ MC Distributor. The installation is started.
→ Follow the instructions on screen.

Installation Manual, Station Software Version 602.01 Edition 06/2006
56 of 60
4.9 Installing the machine controller on a CPU420 (Microbox - SIPLACE
D-Series)
The Microbox only provides a USB interface for installation. For this reason, BIOS updates, automatic
BIOS settings and installation of the RMOS can only be carried out with a CD using an external USB CD
drive.
4.9.1 Installing the RMOS machine controller operating system
The CDs mentioned below (RMOS installation, BIOS update and BIOS settings) can be created from ISO
images located on the installation CD for the station software. These images can be used to create
bootable CDs with suitable CD writing software on a PC with a CD writer. You should do this before
proceeding (see section
4.2).
4.9.1.1 Creating an RMOS installation CD
→ Start a CD writing program on any computer equipped with a CD writer and an additional CD ROM
drive.
→ Insert an empty CD-R in the CD writer.
→ Insert the CD “SW-Version 602.01” in the CD-ROM drive.
→ Start the option for writing an image in the CD writing program.
→ Select the file “BootCD_Install.iso” from the “RMOS-Images” folder on the CD and follow the on-screen
instructions.
→ Once the CD has been written, remove the CDs from the drives.
4.9.1.2 Preparing to install the RMOS on the machine controller
→ Connect a USB keyboard to the machine’s machine controller.
→ Switch video multiplexer to the machine controller.
→ Insert the CD in the USB CD drive and connect the drive to the machine controller using a USB cable.
→ Press <Ctrl><Alt><Del> to warm start the machine controller. The Microbox now boots from CD and
starts the RMOS installation using menu guidance.