00196778-02_VB Setup Center 4.2_DE_EN.pdf - 第34页

System Overview 34 Setup Center 4.2 Setup Center 4.2

100%1 / 56
System Overview
Setup Center 4.2 Setup Center 4.2 33
2 System Overview
The SIPLACE Setup Center package comprises the following subsystems:
Setup Center GUI
Setup Center Database
Barcode Reader
Docking Station
SIPLACE Setup Center loads the target setup from SIPLACE Pro. After the download of a recipe at the
line, Setup Center automatically loads target setup during online setup verification. In the case of offline
setup verification, the operator selects the target setup manually.
During setup verification, packaging unit data are recorded via the barcode reader, then checked against
the currently loaded target setup and finally stored in the Setup Center database. During the process of
forced setup verification, the resulting data is transferred to the machine via the station interface.
System Overview
34 Setup Center 4.2 Setup Center 4.2
Scope of Delivery
Software Components and Documentation
Setup Center 4.2 Setup Center 4.2 35
3 Scope of Delivery
3.1 Software Components and Documentation
SIPLACE Setup Center Basic License V4.x (Item No. 00116730-01)
SIPLACE Setup Center Upgrade License V4.x (Item No.. 00116731-01)
SIPLACE Setup Center Media Package V4.2 (Item No. 00116732-02)
SIPLACE Setup Center V4.2 Setup
Activation of forced setup verification and component level indicator at the station
Sontheim PCI CAN Driver
Basic documents:
"User Manual SIPLACE Setup Center 4.2"
(Item No. 00196776-02 [Deutsch], 00196777-02[English])
This "Software Version Description SIPLACE Setup Center 4.2"
(Item No. 00196778-02 [Deutsch, English])
"Installation Manual SIPLACE Setup Center 4.2"
(Item No. 00196779-02 [English])
Installation Manual WLAN Infrastructure for SIPLACE
(Item No. 00195606-03 [English])
3.2 Languages
SIPLACE Setup Center
English
▪German
NOTICE
No firmware for docking stations or X feeders is included in the scope of delivery of Setup Cent-
er. The firmware can be loaded from the installation CDs of the station software (605.03 and