3 Installation 3.2 Installing the Transformer Assembly Instructions / Montageanleitung SIPLACE TX Series Option 120 V 04/2017 52 Fig.10: Transformer in the machine ► Place the transformer in the upright position in the …

100%1 / 66
Assembly Instructions / Montageanleitung SIPLACE TX Series
Option 120 V 04/2017
3 Installation
3.2 Installing the Transformer
51
3.2 Installing the Transformer
Fig.7: Transformer
The three phases of the output voltage at the trans-
former are secured by means of three safety fuses(1).
In addition, the transformer is provided with three
spare fuses(2).
Remove the three spare fuses and keep them for
future use.
Fig.8: Transformer screw points
1. Screw points for the transformer
CAUTION
Do not damage the cables
Make sure you do not damage the tied-up cables and hoses when performing the fol-
lowing steps.
Fig.9: Inserting the transformer
Observe the orientation of the transformer. The
cables must reach out to the front of the opening.
Tilt the transformer to the side and place it care-
fully into the machine.
3 Installation
3.2 Installing the Transformer
Assembly Instructions / Montageanleitung SIPLACE TX Series
Option 120 V 04/2017
52
Fig.10: Transformer in the machine
Place the transformer in the upright position in
the machine.
Fasten the transformer with four M6x12 screws
and four lock washers (1).
Unplug the bridging plug fitted on the cable(2).
Leave the bridging plug on the cable for a later
retrofitting.
Plug in the transformer cable.
Stow the cable in the machine.
Fig.11: Cover
Mount the cover(1) using two fastening screws.
NOTICE
120V
On machines which use the 120 Voption, the vacuum pump must be set from the star to
the triangle.
A corresponding note is attached directly to the cable which is connected to the transformer
in the machine.
Assembly Instructions / Montageanleitung SIPLACE TX Series
Option 120 V 04/2017
3 Installation
3.3 Exchanging the circuit breaker
53
3.3 Exchanging the circuit breaker
Fig.12: Power supply
Open the door(1) to the power supply.
Fig.13: Main switch unit
Remove the four fastening screws(1) from the
main switch unit.
Fig.14: Circuit breaker [03125553‑xx]
Dismount the circuit breaker "3RV2 3-pole
4.5‑6.3A" [03125553‑xx].