SIPLACE Setup Center 2.2 Installation Manual • Database Version The database is upgraded by the installation. In this step, the current verification data is deleted and the setup must be verified again afte r t he instal…

100%1 / 90
Installation Manual SIPLACE Setup Center 2.2
Fig. 4-1 Decision Tree for SIPLACE Setup Center Database
Questions:
Do the packaging units have Unique ID barcodes?
Each packaging unit in the factory must be marked with a unique barcode. It is possible that
the unique ID is part of a combined barcode.
Do you validate the setup in a pre-setup area?
The pre-setup area is used to validate the setup for correctness and completeness. The
validated tables are docked to the production line(s) for use.
Local database (MSDE)
This scenario does track the numbers of components on each packaging unit. The current
number of components are “remembered” when the packaging unit is torn down. If the
packaging unit is moved to another line the other Setup Center system does not know this
reel and will start with the start quantity. Therefore the operator need to check each partially
fractured packaging unit he gets from the stock and need to adjust the quantity if necessary.
This scenario offers a higher amount of operation safety, because the SIPLACE Setup Center
and a local MSDE database are installed to different computers for each production line. If
one component of SIPLACE Setup Center encounters an error, only one production line is
affected.
Central database
The SIPLACE Setup Center database can be installed to any available Microsoft SQL Server
2000 (SP3a). In this case, the customer is responsible to set up a backup & recovery strategy
and must provide an operating Microsoft SQL Server 2000 (SP3a).
13 of 90
-
SIPLACE Setup Center 2.2 Installation Manual
Database Version
The database is upgraded by the installation. In this step, the current verification data is
deleted and the setup must be verified again after the installation. All data that is connected
to unique IDs (Unique IDs for packaging units and change over tables) will be kept in the
database. This means that after re-verifying the fill-levels of the packaging units are restored.
The database version for SIPLACE Setup Center 2.2 is 1.0.1.5.
The database version for SIPLACE Setup Center 2.1 is 1.0.1.4.
The database version for SIPLACE Setup Center 2.0 is 1.0.1.3.
When working with identical component lots (without Unique IDs), the fill-levels of
the packaging units must be restored manually after the installation (fill-level
corrections).
Database Backup & Recovery Strategy
The setup automatically creates two database jobs, which backup the SIPLACE Setup Center
database. The first job ‘Full backup’ executes a backup of the database and several maintenance
tasks. The job starts every week Sunday at 00.00. The second job ‘Delta backup’ executes only a
backup of the database and starts every day, except Sunday at 00:00. During the backup
SIPLACE Setup Center database is locked and the Setup Center GUI have to wait until unlock.
The backups are stored in “C:\Programme\Siemens SIPLACE\SIPLACE Setup Center\Database”.
A job completion event is written to the Windows application log. More details are written to the
file “SiplaceSetupCenterReport.txt” in the database directory.
4.2.3 Setup Center GUI
It is recommended to install SIPLACE Setup Center GUI once for each line and pre-setup area.
With the “central database” scenario these can use the same database at the same time.
It is recommended to use two barcode scanners per line and SIPLACE Setup Center GUI
installation.
4.2.4 Forced Setup Verification
Activate the forced setup verification at the placement station if it is necessary.
14 of 90
Installation Manual SIPLACE Setup Center 2.2
4.2.5 Docking Stations
The installation of the docking station is necessary; If equipment of the X-Series is used and a pre
setup area or kitting area exists.
15 of 90
-