00197787-02_SI_SIPLACE_HeadVerification_EN.pdf - 第7页
1 Introduction Software Manual SIPLACE Head Verification 03/2018 7 1 Introduction This manual is a handbook for the ‘Head Verification’ feature which can be used to verify the func- tional condition of placement heads …

6 Software Manual SIPLACE Head Verification 03/2018
Table of Contents

1 Introduction
Software Manual SIPLACE Head Verification 03/2018 7
1 Introduction
This manual is a handbook for the ‘Head Verification’ feature which can be used to verify the func-
tional condition of placement heads inside (online) and outside (offline) the machine.
●
The Online Head Verification is available with station SW 708.0 supporting the verification of
placement heads directly in the machine.
●
The Offline Head Verification requires the use of the Head Care Station (HCS) where place-
ment heads can be installed in the same way as on the machine.
The following placement heads can be verified:
●
C&P20
●
C&P20 A
●
C&P20 M
●
C&P20 P
●
C&P20 M2
●
CPP
●
CPP M
●
TH (Pick&Place module)
Types of measurements
A head verification process includes a number of functional tests which can be executed individu-
ally or as a whole sequence to verify a placement head and its sub-units. These functional tests
vary depending on the head to be verified:
●
Condition of the vacuum system and its sub-units
●
Movement of DP and Z-axis bearings
●
Wear on bearings / tolerances
●
Check of the component sensor
●
Check of the z-axis light barrier
●
Check of the nozzle seating
●
Positioning accuracy of DP drives
●
Placement force verification
At the end of the verification process, all results are summarized in a test report which can also be
saved to a PDF file. These results provide feedback about the technical state of the head, enabling
a technician to decide on the measures to be taken, for example:
●
Performing additional maintenance
●
Replacement of wear/spare parts
●
Replacement of the head

1 Introduction
8 Software Manual SIPLACE Head Verification 03/2018