00197964-01_AI_Flex-Head-Options-Configuration_en.pdf - 第13页
Installing Flex Option 1 Assembly Instructions SIPLACE E 13 2 2 I n s t a llin g F le x O p t io n 1 Installing Flex Option 1 ▪ A sta ndard ma chine with NC FLEX std. cpl [ 03107775-xx] is equipped with one m agazine ho …

Introduction
Staff Qualifications and Training 1.3.6 SIPLACE on the World Wide Web (WWW)
12 Assembly Instructions SIPLACE E
1.4
1.4 Staff Qualifications and Training
Staff Qualifications and Training
Qualified or adequately trained personnel means that these people are familiar with the setting up, op
-
eration and maintenance of automatic placement systems and add-on devices and are suitably qualified,
e.g.:
▪ Have been trained, instructed or authorized to switch on and off, isolate, earth and identify electrical
circuits and system components in accordance with normal safety standards.
▪ Have been trained or instructed in the upkeep and use of appropriate safety equipment in accord
-
ance with normal safety standards.
▪ Have received first aid training.
1.5
1.5 Abbreviations
Abbreviations
Abbreviations Description
COT Changeover table
COT-i Changeover table insert
C&P Collect&Place
CPP Collect&Pick&Place head
CPx Collective term for CPP, CP20, CP14, CP12 and/or CP6
CP6 SIPLACE CP6, Collect&Place head with 6 segments
CP12 SIPLACE CP12, Collect&Place head with 12 segments
CP14 SIPLACE CP14, Collect&Place head with 14 segments
EMC Electromagnetic compatibility
ESD Electrostatic sensitive device
HMI Human machine interface (Operator panel)
JTF-MW JEDEC Tray Feeder (Automatic tray changer)
PCB Printed circuit board
P&P Pick&Place
PP SIPLACE PP, Pick&Place head
SC Station computer
TH SIPLACE TH, Twin Pick&Place head

Installing Flex Option 1
Assembly Instructions SIPLACE E 13
2
2 Installing Flex Option 1
Installing Flex Option 1
▪ A standard machine with NC FLEX std. cpl [03107775-xx] is equipped with one magazine holder with
two passive nozzle magazines of type [03103613-xx] and one passive nozzle magazine of type
[03109863-xx] at location 2.1.
▪ The large reject bin [03109719- xx] is located on the left at Location 2. The small reject bin
[03109739-xx] is located on the left at location 1.
Passive Nozzle Magazine Type (Quick Reference)
Standard Flex Flex Option 1
2x Magazine cpl. / 2 nozzles P&P / E-series
[03103613
-
xx]
1x Magazine cpl. / 1 nozzle P&P / E-series
[03109863
-
xx]
1 Location 1 2 Location 2
Flex Option 1 Configuration NC FLEX LOC 2.2 cpl. [03113126-xx] is located at the highlighted area.
It consists of a magazine holder with a flexible number of passive nozzle magazines ([03103613-xx] or
[03109863-xx]).
The order quantity depends on the customer's preference.

Installing Flex Option 1
14 Assembly Instructions SIPLACE E
Installation Procedures (Taking Location 2.1 as an Example)
► Place the height measurement block FLEX LOC2 [03118537-xx] onto the shim cover and move head
holder manually towards the block with care.
► Check the gap with a feeler gauge (1).
► Determine the gap and the number of NC shims [03108395-xx] required.
Magazine holder single and double P+P magazine
► Place the magazine holder cpl./NC P+P/E-series [03103612-xx] onto the shim cover once the height
is adjusted.
► Secure it with four M5x20 cap screws at both ends.
► Height measurement block FLEX LOC2 [03118537-xx] is required to up
-
grade in the field.
► Mount the shim cover [03108393-xx] onto the mounting block Flex
[03106636-xx] at location 2.
► Mount the required shims underneath the shim cover and fasten them
with an M3x8 countersunk screw.