SOM-1627-002.pdf - 第65页
1 1. Component Library Data Sheets This section describes the data sheets to be filled in with the measured dimensions of a component, etc. • • • • • Frame Line of Sheets : T o be filled with standard data : T o be fille…

(4) Component Recognition Lighting Lamp Burnout Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification (0)
Primary Error Classification (0)
Classification of Recognition Functions
(13)
Table 22
Recognition Error ID Item Description
13 00 0 00003 ---- The lamp for Front Lighting 3 (Ring 2) has
blown in the component recognition light-
ing unit.
(Cause 1) The lamp of the component recognition lighting device was burnt out.
(Remedy 1) Replace the lamp with a new one.
After the replacement, perform the teaching operation required for compo-
nent recognition.
0102-001 62 AGQ01EGP
10.4 Recognition Error IDs and Remedial Procedures

11. Component Library Data Sheets
This section describes the data sheets to be filled in with the measured
dimensions of a component, etc.
••
••
• Frame Line of Sheets
: To be filled with standard data
: To be filled with extended data
11.1 Sheets for BGA/CSP Components
Date of Preparation
Prepared by
Classification Data
Component ID
Comment
Component Shape BGA/CSP
Component Type R (Resistor), C (Capacitor), L (Coil), FL (Filter),
DI (Diode), TR (Transistor), IC,
VR (Variable Resistor), LED (Light Emitted Diode),
TC (Trimmer Capacitor), T (Transformer),
CN (Connector), SW (Switch),
CSA (Ceramic Sense Amplifier Oscillator,
ETC (Others)
Control Data (1)
Speed Data Pick-Up [sec] . second
Head transfer . second
Rotary turret [sec] . second
X/Y table Full Speed
10 20 30 40 50
60 70 80 90 %Decr
Feeder carriage Full Speed
10 20 30 40 50
60 70 80 90 %Decr
Nozzle rotation Full Speed
10 20 30 40 50
60 70 80 90 %Decr
Recognition time . second
[sec]
11. Component Library Data Sheets
0102-001 63 AGQ01EGP

0102-001 64 AGI01JGP
Control Data (2)
Selected nozzle
Placement height Enable, Disable
feedback
Cmpnt thickness . mm
check [mm]
Vertical cmpnt . mm
data [mm]
Pickup level [mm] +/− . mm
Placement level [mm] +/− . mm
Pickup pos correction X +/− . mm
Y +/− . mm
Carrier Data
Carrier Data Type Paper, Embossed, Adhesive,
Bulk 1, Bulk 2
Tape width [mm] 8, 12, 16, 24, 32, 44 mm
Tape feed pitch [mm] 2, 4, 8, 12, 16, 24, 32 mm
Tape feed counts 1, 2, 3, 4, 5, 6, 7, 8, 9
Direction 0°, 45°, 90°, 135°, 180°,
225°, 270°, 315°
Q’ty pcs.
Tape end Enable, Disable
detection
11. Component Library Data Sheets
Auto fdr axis X Enable, Disable
adjustment Y Enable, Disable
Error process 1 1, 2, 3, 4, 5, 6, 7, 8, 9
2 1, 2, 3, 4, 5, 6, 7, 8, 9