SECS GEM Manual.pdf - 第111页
GEM Manual for DEK Printers Equipment Variables Issue 1.6 January 22, 2018 Page 111 of 171 BoardSto pXOffset 86 The current ca mera board stop X offset F8 25 -254 mm No CameraIdlePosition 88 The current selection for the…

GEM Manual for DEK Printers Equipment Variables
Issue 1.6 January 22, 2018 Page 110 of 171
ToolingHardware 62 The currently selected tooling
harware
U1
0=Magnetic
2=Vacuum
6=FormFlex
7=GridLok
8=ProductDefined
9=EnhancedVacuum
No
FiducialReference 63 The current fiducial reference U1
0=Left
1=Right
Yes
ProductBarcodeHardware 64 The status of the product barcode
scanner
U1
0=Not Fitted
1=Fitted
No
RemoteBarcodeHardware
65 The status of the remote barcode
scanner
U1
0=Not Fitted
1=Fitted
No
AdvancedProflow
66 Status of the Advanced ProFlow
option
U1
0=Disabled
1=Enabled
Yes
PressureHardware
67 The currently selected pressure
hardware
U1
0=NotFitted
1=Fitted
No
PasteDispenser 68 The status of the automatic paste
dispenser
U1
0=NotFitted
1=Fitted
No
ScreenSize 69 The current screen type selection U1
0=265
1=Fuji
2=249
3=Sanyo
4=Library
Yes
RollHeightHardware 70 The current selection of the Paste
Roll Height Monitor (PRHM)
hardware
U1
0=NotFitted
1=Fitted
No
RollHeightMonitor 72 The current status of the PRHM
option
U1
0=Disabled
1=Enabled
Yes
ConsumableAction 73 The current setting for the action to
perform when a consumable is low
U1
0=Warn
1=Pause
2=Suspend
Yes
VacuumHoldTime
74 The time the vacuum is applied to the
tolling before the quality of the
vacuum seal is checked (s)
F8 0-5 s Yes
TwoDiMovementTuning
75 The settling time used in 2D
Inspection per site (ms)
U2 0-250 ms Yes
CleanerVacuum
76 The current status of the cleaner
vacuum option
U1
0=Standard
1=Vacuum
No
PasteTrails
77 The current status of the paste trails
option
U1
0=Disabled
1=Enabled
Yes
TransportWaitMode 78 The current setting for the transport
wait mode
U1
0=Standard
1=Hold At Print
Yes
ClampType
80 The current selection for the board
clamp type
U1
0=Board Clamps
1=Snuggers
2=Foil Less Clamps
3=Over The Top
Snuggers
No
ToolingMonitoring
81 The rate (in boards) that the Tooling
Deviation Monitoring option is used
U2 0 – 200 Yes
FiducialMonitoring
83 The current selection for the Fiducial
Monitoring option
U1
0=Smart
1=Normal
Yes
FiducialSearch
84 The current selection for the Fiducial
Search option
U1
0=Disabled
1=Custom
Yes
RemoteBoardStopHardware 85 The current selection for the Remote
Board Stop hardware
U1
0=NotFitted
1=Fitted
No

GEM Manual for DEK Printers Equipment Variables
Issue 1.6 January 22, 2018 Page 111 of 171
BoardStopXOffset
86 The current camera board stop X
offset
F8 25-254 mm No
CameraIdlePosition 88 The current selection for the Camera
Idle Position option
U1
0=Home
1=Behind Rail
No
UnloadBoardStart
89 The current selection for the Unload
Board Start option
U1
0=Transport
1=Separation
Yes
MaintenanceMonitoring
95 The current state of the Maintenance
Monitoring option
U1
0=Disabled
1=Enabled
Yes
MachineLocation
96 Free format entry to describe the
location of the machine
A20 Up to 20 characters No
AutoRailWidth
97 The current selection for the
Automatic Rail Width option
U1
0=Disabled
1=Enabled
No
ProductDirectory
98 The path to the local folder where the
product files are stored
A260 Up to 260 characters No
DataFileLocation 99 The path to the local folder where
data and log files are stored
A260 Up to 260 characters No
DownlineBoardStop
101 The current selection of the HTC
Downline Board Stop option
U1
0=Never
1=Always
2=Auto
Yes
FrontRToLSpeed
104 The speed of the front rail belt when
running from right to left
U2 0-32000- 64000 No
FrontLToRSpeed
105 The speed of the front rail belt when
running from left to right
U2 0-32000- 64000 No
RearRToLSpeed
106 The speed of the rear rail belt when
running from right to left
U2 0-32000- 64000 No
RearLToRSpeed 107 The speed of the rear rail belt when
running from left to right
U2 0-32000- 64000 No
AltFrontRToLSpeed
108 The alternate speed of the front rail
belt when running from right to left
U2 0-32000- 64000 No
AltFrontLToRSpeed
109 The alternate speed of the front rail
belt when running from left to right
U2 0-32000- 64000 No
AltRearRToLSpeed
110 The alternate speed of the rear rail
belt when running from left to right
U2 0-32000- 64000 No
AltRearLToRSpeed
111 The alternate speed of the rear rail
belt when running from right to left
U2 0-32000- 64000 No
VacuumPressureRequired 153 The current value of the Vacuum
Pressure (Required) parameter
F8 -100 - -35 - 0 Yes
VacuumValve 154 The current value of the Vacuum
Valve parameter
F8 0 – 100% Yes

GEM Manual for DEK Printers Equipment Variables
Issue 1.6 January 22, 2018 Page 112 of 171
6.3 Status Variables
The status variables are defined in the table below:
Name SVID
Limits
Monitor
Description Type Value Range
GemAlarmsEnabled 1001
No
List of alarms that are enabled. List A list of “n” ALID’s.
GemAlarmsSet 1002
No
List of alarms that are set. List A list of “n” ALID’s.
See chapter 6 for ALID’s.
GemAlarmState 1003
No
State of last alarm transition. U1 0 = OFF
1 = ON
clock 1004
No
Host view of equipment time.
(centisecond precision)
A12/A16
Yymmddhhmmss
Yyyymmddhhmmsscc
GemControlState 1005
No
Current GEM Control State. U1 1 = Equipment Off-Line
2 = Attempt On-Line
3 = Host Off-Line
4 = Local
5 = Remote
process_state 1006
No
Current Equipment Process State. U1 0 = Equipment Ready
1 = Equipment Waiting
2 = Equipment Running
3 = Equipment Setup
4 = Equipment Down
5 = Equipment Recovery
6 = Equipment Maintenance
GemEventsEnabled 1007
No
List of collection events enabled. List A list of “n” CEID’s.
See chapter 7.
humidity 1008 Yes Current humidity in print area. F4 0-100 %
model_number 1009
No
Model number. A6 String
previous_command 1010
No
Last command received from operator
or host.
A See appendix A.
GemPreviousControlState
1011
No
Control state prior to last transition. U1 See GemControlState.
last_process_state 1012
No
Process state before last transition. U1 See process_state.
GemPreviousCeid 1013
No
CEID of last collection event to occur.
U4 See chapter 7.
Reserved 1014
No
software_version 1015
No
Software revision 6 char ASCII. A6 See chapter 4. (SOFTREV)
temperature 1016 Yes Current temperature in the print area. F4 0 -100 (Celsius)
current_time 1017
No
Host view of equipment time.
(1 second precision)
A12/A16
Yymmddhhmmss
Yyyymmddhhmmsscc
system_mode 1018
No
The current machine mode. U1 0 = Step
1 = Auto
2 = Single
3 = No Print
PPExecName 1019
No
Name of cu
rrent process program. A68
batch_count 1020 Yes
Number of Boards printed.
U4 0-99999
Reserved 1021
No
time_last_print 1022
No
Time of the last print. A12/
A16
Yymmddhhmmss/
Yyyymmddhhmmsscc