SECS GEM Manual.pdf - 第92页
GEM Manual for DEK Printers SECS II Implementation Issue 1.6 January 22, 2018 Page 92 of 171 S6F11 Event Report Send (ERS) S6F12 Event Report Acknowledge (ERA) Description: The message enable s the equipment to report th…

GEM Manual for DEK Printers SECS II Implementation
Issue 1.6 January 22, 2018 Page 91 of 171
5.6 STREAM 6: DATA COLLECTION
S6F1 Trace Data Send (TDS)
S6F2 Trace Data Acknowledge (TDA)
Description: TDS is a time driven status report. If a trace has been set up using (S2F23)
TIS, the equipment will periodically send TDS messages (period defined in TIS).
A. Host Initiated - Not applicable
B. Equipment Initiated
Equipment to host: S6F1
Structure: L,4
1. <TRID>
2. <SMPLN>
3. <STIME>
4. L,n
1. <SV1>
.
.
n. <SVn>
Host to equipment: S6F2
Structure: <ACKC6>
S6F5 Multi-block Data Send Inquire (MBI)
S6F6 Multi-block Grant (MBG)
Description: If the discrete data report S6F3, F9, F11, F13 can involve more than one
block, this transaction must precede the transmission.
A. Host Initiated - Not applicable
B. Equipment Initiated
Equipment to host: S6F5
Structure: L,2
1. <DATAID>
2. <DATALENGTH>
Host to equipment: S6F6
Structure: <GRANT6>

GEM Manual for DEK Printers SECS II Implementation
Issue 1.6 January 22, 2018 Page 92 of 171
S6F11 Event Report Send (ERS)
S6F12 Event Report Acknowledge (ERA)
Description: The message enables the equipment to report the occurrence of an event
CEID, and to send any reports RPTID’s that have been defined and linked to the event.
The equipment can only send ERA for an event that is enabled.
A. Host Initiated - Not applicable
B. Equipment Initiated
Equipment to host: S6F11
Structure: L,3
1. <DATAID>
2. <CEID>
3. L,a
1. L,2
1. <RPTID1>
2. L,b
1. <V1>
.
.
b. <Vb>
.
.
a. L,2
1. <RPTIDa>
2. L,c
1. <V1>
.
.
c. <Vc>
Host to equipment: S6F12
Structure: <ACKC6>

GEM Manual for DEK Printers SECS II Implementation
Issue 1.6 January 22, 2018 Page 93 of 171
S6F15 Event Report Request (ERR)
S6F16 Event Report Data (ERD)
Description: The host can use this transaction to demand a specified report group from
the equipment. Note that discrete data variables will have indeterminate values.
A. Host Initiated
Host to equipment: S6F15
Structure: <CEID>
Equipment to host: S6F16
Structure: Identical to S6F11.
Exception: A zero length list indicates there are no reports linked to the
specified CEID.
B. Equipment Initiated - Not applicable.
S6F19 Individual Report Request (IRR)
S6F20 Individual Report Data (IRD)
Description: The host can request a defined report to send. The report does not have to
be linked to a CEID, therefore no CEID are required to be enabled.
A. Host Initiated
Host to equipment: S6F19
Structure: <RPTID>
Equipment to host: S6F20
Structure: L,n ; n = No. of variable data items
1.<V1>
.
.
n. <Vn>
Exception: If n = 0 then the report RPTID does not exist.
B. Equipment Initiated - Not applicable.