4 Pneumatic and pressure control valve (PRV) 4.8 Replacing the force measuring unit and the trick and feather unit Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 61 Fig.110: Holder and pipe clamp vers…

100%1 / 92
4 Pneumatic and pressure control valve (PRV)
4.8 Replacing the force measuring unit and the trick and feather unit
60 Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020
Fig.107: Force transducer
► Fit the force transducer. Fix carefully
into place with a screw.
 NOTICE!
Fit the adjustment wedge correctly!
The adjustment wedge has a curved
and a straight side.
Insert the adjustment wedge so that
the straight side faces the sensor.
.
Fig.108: Force measuring unit
► Fix the force measuring unit into place
with the two fastening screws (hand-
tight).
Fig.109: Connecting the control cable
► Connect the control cable and fix it with
the lock.
► Fit the hose guidance, the flat ribbon baffle and the stopper.
3.3 "Replacing the hose and flat ribbon guide (Twin HF only)" [}23]
► Fit the sleeve with ball fixing with a new seal.
4.6 "Replacing the sleeve with ball fixing/seal" [}43]
4 Pneumatic and pressure control valve (PRV)
4.8 Replacing the force measuring unit and the trick and feather unit
Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 61
Fig.110: Holder and pipe clamp versions
 NOTICE!
Different holder and pipe clamp ver-
sions!
There are two different versions of the
holder and pipe clamp. These are also
set differently.
(1) Old version (loose)
(2) New version (fixed)
.
Fig.111: Fitting the new holder and pipe clamp
New holder and pipe clamp
► Connect the hoses to the holder, pipe
clamp and rotary supply.
► Attach the holder and pipe clamp and
fix into place with a screw.
► Set the hose(2) so that this runs dir-
ectly between the rotary supply and the
holder plus pipe clamp.
► The rotary supply(1) must sit in the
center of the fly wheel without exerting
any side forces.
Fig.112: Check the new holder and pipe clamp
 NOTICE!
Check the new holder and pipe
clamp!
Make sure that the hose runs parallel
to the pipes.
.
4 Pneumatic and pressure control valve (PRV)
4.8 Replacing the force measuring unit and the trick and feather unit
62 Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020
Fig.113: Fitting the old holder and pipe clamp
Old holder and pipe clamp
► Insert the holder and pipe clamp into
the mount so that the end of the pipe
faces upwards.
► Fix the holder and pipe clamp into
place with the grub screw.
► Connect the hoses to the holder, pipe
clamp and pneumatic rotary supply.
► Set the hose(2) so that this runs
straight between the pneumatic rotary
supply and the holder plus pipe clamp.
► The pneumatic rotary supply(1) must
sit in the center of the fly wheel without
exerting any side forces.
4.8.4 Setting the force measuring unit
Fig.114: Setting the force measuring unit
► Set the actuator of the force measuring
unit so that it is centered and parallel.
To do this, move the plate, which holds
the actuator in place, back and forth.
 NOTICE!
Observe the position of the pins!
The actuator pins must be aligned
straight to the connection disk on both
sides.
.
Fig.115: Set the Z axis
► Use a spring-type dial gauge to press
the Z axis until the inner pins touch the
contact disk.
Target value when touching: 20N
► If not: use adjustment shims to adjust
the setting and repeat the measure-
ment.
► Fit the buffer on the return unit.
3.1 "Replacing the return unit buffer" [}17]