LS-Ge.pdf - 第3页

Operating characteristics Options Actuator Name Shape 13.4 N 8.9 N 8.9 N 8.9 N 1.4 N 1.4 N 13.4 N 13.4 N Max. O.F. (operating force) Max. P.T. (pretravel) Min. T.T. (total travel) Basic catalog listing With LED lamp, 12 …

100%1 / 28
Roller lever Plunger Side roller plunger Roller plunger Fork lever lock
Non-directional operation type
Catalog listing
Model
Between non-continuous terminals : 1,000 Vac, 50/60 Hz for 1 minute (standard operating characteristics type)
: 600 Vac, 50/60 Hz for 1 minute (roller lever, high sensitivity characteristics type)
Between each terminal and non-live metal part : 2,000 Vac, 50/60 Hz for 1 minute.
Between each terminal and ground : 2,000 Vac, 50/60 Hz for 1 minute (only G-type products with ground terminals).
Compliance
Certification *1
Contact form
Contact type
Standard load
Low current load
Terminal type
Protective structure
Pollution level
Electrical rating
Dielectric strength
Insulation resistance
Initial contact
resistance
Standard load
Low current load
Connector
Contact voltage/min.current
Item
Standards
Structure
Electrical
performance (1):
General
characteristics
2-circuit double break
NECA C 4508/JIS C 8201-5-1, IEC 60947-5-1
UL1054, CSA C22.5 No.55, EN 60947-5-1, GB 14048.5-2001
Silver, rivet
Gold-plated silver, rivet
M4 screw (binding head machine screw with toothed washer), DIN 4-pin connector (M12 size), preleaded
IP67 (IEC60529, JIS C 0920)
3 (EN 60947-5-1)*2
See page D-026.
Min. 100 MΩ(by 500 Vdc megger)
Max. 50 mΩ(6 to 8 Vdc, thermal current 1A, voltage drop method)
Max. 100 mΩ(6 to 8 Vdc, thermal current 0.1A, voltage drop method)
Max. 40 mΩ(excluding fixed resistance such as cable)
24V 10 mA, 12V 20 mA (standard load), 5V 10 mA (low current load)
3LS1-J
Mechanical
performance
Rated operating voltage
Rated thermal current (Ith)
Rated frequency
Short-circuit protection
Rated insulating voltage (Ui)
Rated conditional short-circuit current
Switching overvoltage
Rated impulse dielectric strength (Uimp)
Actuator strength
Terminal strength
Impact resistance
Life
Ambient
operating
conditions
120/240 Vac, 30 Vdc
Electrical
performance (2)
EN60947-5-1
GB140 48.5-
2001
Vibration resistance
Allowable
operating speed
Cable pullout strength
Operating frequency
Mechanical life
Electrical life
Temperature
Humidity
Recommended
tightening
torque
Body
Lever
Terminal
Cover
Head
Cap nut
Piano wire lever
Connector tightening torque
Max. 98% RH*3
Front: 5 to 6 N•m (M5 hexagon socket head cap screw). Back: 5 to 6 N•m (M6 screws)
4 to 5.2 N•m (M5 hexagon socket head bolt)
1.0 to 1.4 N•m (M4 binding head machine screw)
1.3 to 1.7 N•m (M4 small round head screw)
0.8 to 1.2 N•m (M3.5 small round head screw)
2 to 3 N•m (M22 screw for 3LS)
0.6 to 0.8 N•m (M3 hexagon head set screw)
0.4 to 0.6 N•m (M12 ring)
Model
Life
Model
Life
Other than on the right
1LS-J50, 2LS-J6, cold-resistant type
3LS1-J
Min. 10 million operations Min. 1 million operations Min. 5 million operations Min. 2 million operations
Standard load built-in switch Standard load double seal built-in switch Low current load built-in switch
Min. 500,000 operations at rated load
Min. 200,000 operations at rated load
Min. 2 million operations at rated load
(At 70% to 100% of the rated overtravel.)
Operating frequency: Above conditions must be satisfied at 20 operations/minute.
Min. 100 N
Light operation roller lever/ heat-resistant/ cold-resistant: max. 60 operations/minute, Models other than the above: max. 120 operations/minute
Other than on the right
0.5 m/s
1.7 mm/s
2LS1-J
0.5 m/s
1.0 mm/s
2LS-J6
0.2 m/s
1.0 mm/s
1LS19-J
0.5 m/s
0.4 mm/s
3LS1-J
0.3 m/s
0.5 mm/s
8LS3-J
0.5 m/s
10 mm/s
8LS125-J
0.3 m/s
50 mm/s
8LS152-J
0.3 m/s
20 mm/s
0.5 m/s
0.2 mm/s
5LS1-J/5LS7-J
Model
Max.
Min.
Silver contacts: 10A. Gold-plated contacts: 1A.
45 to 65 Hz and DC
TÜV F10A fuse (IEC 60127) / CQC instant blowing fuses: silver contacts 15A, gold contacts 3A / TÜV
125 / 250 Vac
1,000A
Category III (IEC 60204-1)
Between each terminal and ground, and between terminals: 2,500V.
Withstands load 5 times O.F. for 1 minute (in operating direction)
Withstands tightening torque of 1.5 N
·
m for 1 minute
Notes: Mechanical performance values for the roller lever type are for lever length of 38.1 mm.
*1. Some models do not fall under this category. *2. EN 60947-5-1 and GB 14048.5-2001 applies only to G-type products with a gr
ound terminal. *3. Max. 95% RH for
connector and preleaded connector types
EN60947-5-1
(
N.O.
)
4 3
(
N.O.
)
Za
2
(
N.C.
)(
N.C.
)
1
N.O.4
N.C.1 N.C.2
N.O.3
Standard model (standard load and low current load) : –10 to +70˚C(freezing not allowed)
Double seal type : 1LS19-JS: 0 to +70˚C(freezing not allowed)
2LS, 3LS,5LS, 8LS125-JS: +5 to +70˚C(freezing not allowed)
Double seal type other than above: –5 to +70˚C(freezing not allowed)
Heat-resistant type : –10 to +120˚C(freezing not allowed)
Cold-resistant type : –40 to +70˚C(freezing not allowed)
High sensitivity roller lever type
Light operation roller lever & non-directional roller lever types
Non-directional operation type
Models other than the above
200 m/s
2
in free and total travel positions
200 m/s
2
in total travel position
300 m/s
2
in total travel position
300 m/s
2
in free and total travel positions
Contact opening for 1 ms max. in free and total travel positions (NECA C 4508)
At max. speed, actuator is not damaged. At min. speed, contact instability lasts 0.1 s max.
High sensitivity roller lever type & non-directional type
Models other than the above
In total travel position
In free and total travel positions
1.5 mm peak-to-peak amplitude, frequency 10 to 55 Hz, for 2 continuous hours (NECA C 4508)
Contact opening for 1 ms max. in free and total travel positions
2-circuit
double break
8LS-J2LS-J1LS-J 5LS-J 6LS-J
6LSJ, heat-resistant type
Contact type
PERFORMANCE
D-024
LIMIT SWITCHES
WITH POSITIVE
OPENING MECHANISM
GENERAL PURPOSE
LIMIT SWITCHES
TECHNICAL GUIDE
FOR
LIMIT SWITCHES
EXPLOSION-PROOF
SWITCHES
TECHNICAL GUIDE FOR
EXPLOSION-PROOF
SWITCHES
F-001
See page
Connector
with cable
SPATTER-GUARDED
LS
1LS-J7
1LS-J8
VCL-
1LS-J401
SL1-
SL1-C
PHOTOELECTRIC
SENSORS &
SWITCHES
MEASUREMENT
SENSORS
PROXIMITY
SWITCHES
LIMIT
SWITCHES
SAFETY
KEY SWITCHES
STANDARD
LS
Operating characteristics
Options
Actuator
Name Shape
13.4 N
8.9 N
8.9 N
8.9 N
1.4 N
1.4 N
13.4 N
13.4 N
Max. O.F.
(operating force)
Max. P.T.
(pretravel)
Min. T.T.
(total travel)
Basic catalog
listing
With LED lamp,
12 to 125 Vac/dc
EC
With neon lamp,
100/200 Vac
E
Double seal
S
Roller
lever
Adjustable
roller lever
*1
Light operation
rod lever
*2
Lever-less
type
Standard model
20˚
High sensitivity
Standard model
20˚
High sensitivity
10˚
Standard model
30˚
Standard model
20˚
Standard model
20˚
High sensitivity
10˚
Standard model
20˚
Standard model
20˚
High sensitivity
Standard model
20˚
High sensitivity
10˚
Standard model
30˚
Standard model
20˚
Standard travel50˚
Standard travel50˚
High overtravel80˚
High overtravel80˚
High overtravel90˚
Standard travel50˚
High overtravel80˚
High overtravel80˚
Standard travel50˚
Standard travel50˚
Standard travel50˚
High overtravel80˚
High overtravel80˚
High overtravel90˚
Standard travel50˚
1LS1-J
1LS19-J
1LS-J500
1LS-J550
1LS-J50
1LS3-J
1LS-J503
1LS-J553
1LS10-J
1LS2-J
1LS9-J
1LS-J501
1LS-J551
1LS-J51
1LS23-J
1LS1-JEC
1LS19-JEC
1LS-J500EC
1LS-J550EC
1LS-J50EC
1LS3-JEC
1LS-J503EC
1LS-J553EC
1LS10-JEC
1LS2-JEC
1LS9-JEC
1LS-J501EC
1LS-J551EC
1LS-J51EC
1LS1-JE
1LS19-JE
1LS-J500E
1LS-J550E
1LS-J50E
1LS3-JE
1LS-J503E
1LS-J553E
1LS10-JE
1LS2-JE
1LS-J501E
1LS-J551E
1LS-J51E
1LS23-JE
1LS1-JS
1LS19-JS
1LS-J500S
1LS-J550S
1LS-J50S
1LS3-JS
1LS-J503S
1LS-J553S
1LS10-JS
1LS2-JS
1LS-J501S
1LS-J551S
1LS-J51S
Plunger
Ball
plunger
Side roller
plunger
Roller
plunger
Boot seal
roller plunger
Fork lever
lock
Spring
rod
Steel wire
light operation
Coil
spring
26.7 N
26.7 N
40.1 N
26.7 N
15.7 N
8.9 N
8.9 N
1.4 N
0.28 N
1.4 N
1.7 mm
1.7 mm
2.77 mm
1.7 mm
1.7 mm
60˚
60˚
28.6 mm
55 mm
28.6 mm
8.1 mm
5.7 mm
8.4 mm
7.3 mm
7.3 mm
90˚
90˚
2LS1-J
2LS-J6
3LS1-J
5LS1-J
5LS7-J
6LS1-J
6LS3-J
8LS3-J
8LS125-J
8LS152-J
2LS1-JEC
2LS-J6EC
3LS1-JEC
5LS1-JEC
5LS7-JEC
6LS1-JEC
6LS3-JEC
8LS3-JEC
8LS125-JEC
8LS152-JEC
2LS1-JE
2LS-J6E
3LS1-JE
5LS1-JE
5LS7-JE
6LS1-JE
6LS3-JE
8LS3-JE
8LS125-JE
8LS152-JE
2LS1-JS
3LS1-JS
5LS1-JS
5LS7-JS
6LS1-JS
6LS3-JS
8LS3-JS
8LS125-JS
8LS152-JS
*1. Values are for lever length of 38.1 mm.
*2. Values are for lever length of 141.2 mm.
UL/CSA/GB (ccc marking) approved products
UL/CSA/CE/GB-approved products
All catalog listing are GB approved products.
*1
*1
*2
Non-directional operation type
ORDER GUIDE
Switch body (contact your dealer for models not listed in the following table)
D-025
LIMIT SWITCHES
WITH POSITIVE
OPENING MECHANISM
GENERAL PURPOSE
LIMIT SWITCHES
TECHNICAL GUIDE
FOR
LIMIT SWITCHES
EXPLOSION-PROOF
SWITCHES
TECHNICAL GUIDE FOR
EXPLOSION-PROOF
SWITCHES
SPATTER-GUARDED
LS
1LS-J7
1LS-J8
VCL-
1LS-J401
SL1-
SL1-C
PHOTOELECTRIC
SENSORS &
SWITCHES
MEASUREMENT
SENSORS
PROXIMITY
SWITCHES
LIMIT
SWITCHES
SAFETY
KEY SWITCHES
STANDARD
LS
Options
Double seal
+ LED
SEC
Double seal
+ neon lamp
SE
Low current
load
K
EN/GB-compliant
with GND
terminal
G
EN/GB-compliant
with GND
+ LED
GEC
EN/GB-compliant
with GND + LED
& dbl seal
SGEC
Corrosion-resistant
type
M
Heat-resistant
type
H
Cold-resistant
type
L
1LS1-JSEC
1LS19-JSEC
1LS-J500SEC
1LS-J550SEC
1LS-J50SEC
1LS3-JSEC
1LS-J503SEC
1LS-J553SEC
1LS10-JSEC
1LS-J551SEC
1LS1-JSE
1LS19-JSE
1LS-J500SE
1LS-J550SE
1LS3-JSE
1LS-J503SE
1LS10-JSE
1LS1-JK
1LS19-JK
1LS-J500K
1LS-J550K
1LS-J50K
1LS3-JK
1LS-J503K
1LS-J553K
1LS10-JK
1LS9-JK
1LS-J501K
1LS-J51K
1LS1-JG
1LS19-JG
1LS-J500G
1LS-J550G
1LS-J50G
1LS3-JG
1LS-J503G
1LS-J553G
1LS10-JG
1LS1-JGEC
1LS19-JGEC
1LS-J500GEC
1LS-J550GEC
1LS-J50GEC
1LS3-JGEC
1LS-J503GEC
1LS-J553GEC
1LS10-JGEC
1LS2-JGEC
1LS9-JGEC
1LS-J501GEC
1LS-J551GEC
1LS-J51GEC
1LS1-JSGEC
1LS19-JSGEC
1LS-J500SGEC
1LS-J550SGEC
1LS-J50SGEC
1LS3-JSGEC
1LS-J503SGEC
1LS-J553SGEC
1LS10-JSGEC
1LS2-JSGEC
1LS9-JSGEC
1LS-J501SGEC
1LS-J551SGEC
1LS-J51SGEC
1LS1-JM
1LS19-JM
1LS-J500M
1LS-J550M
1LS3-JM
1LS-J503M
1LS2-JM
1LS1-JH
1LS19-JH
1LS-J500H
1LS-J550H
1LS-J50H
1LS3-JH
1LS-J503H
1LS2-JH
1LS1-JL
1LS19-JL
1LS-J500L
1LS3-JL
1LS-J503L
1LS-J501L
1LS-J51L
2LS1-JSEC
2LS-J6SEC
3LS1-JSEC
5LS1-JSEC
5LS7-JSEC
6LS1-JSEC
6LS3-JSEC
8LS3-JSEC
8LS125-JSEC
8LS152-JSEC
2LS1-JSE
2LS-J6SE
3LS1-JSE
5LS1-JSE
5LS7-JSE
6LS1-JSE
8LS125-JSE
8LS152-JSE
2LS1-JK
2LS-J6K
3LS1-JK
5LS1-JK
5LS7-JK
6LS1-JK
6LS3-JK
8LS3-JK
8LS125-JK
8LS152-JK
2LS1-JG
2LS-J6G
3LS1-JG
5LS1-JG
5LS7-JG
6LS1-JG
6LS3-JG
8LS3-JG
2LS1-JGEC
2LS-J6GEC
3LS1-JGEC
5LS1-JGEC
5LS7-JGEC
6LS1-JGEC
6LS3-JGEC
8LS3-JGEC
8LS125-JGEC
8LS152-JGEC
2LS1-JSGEC
2LS-J6SGEC
3LS1-JSGEC
5LS1-JSGEC
5LS7-JSGEC
6LS1-JSGEC
6LS3-JSGEC
8LS3-JSGEC
8LS125-JSGEC
8LS152-JSGEC
2LS1-JM
2LS1-JH
5LS1-JH
8LS3-JH
3LS1-JL
5LS1-JL
8LS152-JL
D-026
LIMIT SWITCHES
WITH POSITIVE
OPENING MECHANISM
GENERAL PURPOSE
LIMIT SWITCHES
TECHNICAL GUIDE
FOR
LIMIT SWITCHES
EXPLOSION-PROOF
SWITCHES
TECHNICAL GUIDE FOR
EXPLOSION-PROOF
SWITCHES
F-001
See page
Connector
with cable
SPATTER-GUARDED
LS
1LS-J7
1LS-J8
VCL-
1LS-J401
SL1-
SL1-C
PHOTOELECTRIC
SENSORS &
SWITCHES
MEASUREMENT
SENSORS
PROXIMITY
SWITCHES
LIMIT
SWITCHES
SAFETY
KEY SWITCHES
STANDARD
LS