LS-Ge.pdf - 第7页

LS Series connectors Catalog listing Name Appearance Power supply Number of leads 2 leads 4 leads LS-PA5A2 LS-PA5A4 LS-PA5D2 LS-PA5D4 2-lead type 4-lead type AC — — DC — — Assembly method PA5 Series sealed connector with…

100%1 / 28
General-purpose
General-purpose
(high sensitivity)
General-purpose,
double seal
General-purpose,
gold plated contacts
General-purpose
(high sensitivity),
dbl seal
General-purpose,
DC connector/
preleaded connector
General-purpose,
AC connector/
preleaded connector
Indicator type None 100/200 Vac with neon lamp 12 to 125 Vac/dc with LED lamp
Model Catalog listing Electrical rating Catalog listing Electrical rating Catalog listing Electrical rating
125 Vac 0.1A
30 Vdc 0.1A
125, 250, 480 Vac 10A
125 Vac 1/2HP
250 Vac 1HP
125 Vdc 0.8A
250 Vdc 0.4A
125, 250 Vac 5A
125 Vac 1/8HP
250 Vac 1/4HP
125 Vdc 0.8A
250 Vdc 0.4A
125, 250, 480 Vac 10A
125 Vac 1/8HP
250 Vac 1/4HP
125 Vdc 0.4A
250 Vdc 0.2A
125, 250 Vac 5A
125 Vac 1/8HP
250 Vac 1/4HP
125, 250 Vac 5A
125, 250 Vac 5A
125, 250 Vac 5A
125, 250 Vac 5A
125 Vac 0.1A
125 Vac 5A
125 Vac 5A
125 Vac 5A
125 Vdc 0.8A
125 Vac 5A
125 Vdc 0.8A
125 Vac 0.1A
30 Vdc 0.1A
30 Vdc 3A
125 Vac 3A
30 Vdc 3A
ELECTRICAL RATING
2-circuit double break
LS-J
LS-JS
LS-JK
1LS19-J
1LS-J55
1LS19-JS
1LS-J55S
LS-JE
LS-JSE
LS-JKE
1LS19-JE
1LS-J55E
1LS19-JSE
1LS-J55SE
LS-JEC
LS-JSEC
LS-JKEC
1LS19-JEC
1LS-J55EC
1LS19-JSEC
1LS-J55SEC
LS-JEC-PD
LS-JEC-PD03
LS-JEC-PA
LS-JEC-PA03
Application category Rating Rated thermal current (Ith)
Standard load type
3.0A 240 VacAC-15 10A
0.4A 30 VdcDC-12 10A
0.1A 125 VacAC-12 1A
0.1A 30 VdcDC-12
1A
Low current load type
AC rating
125 Vac 250 Vac 480 Vac
Typical model:
1LS1-J
Typical model:
1LS1-J
Resistance
Induction
Electric motor
N.C. N.O.
Resistance
Induction
Electric motor
N.C. N.O.
Resistance
Induction
6 43
DC rating
8 Vdc 14 Vdc 30 Vdc 115 Vdc 230 Vdc
Resistance
Induction
Resistance
Induction
Resistance
Induction
Resistance
Induction
Resistance
Induction
10
10
10
10
6
6
6 1.5
4 2
66 4 0.8 0.2 0.4 0.1
Note: "Induction" refers to a load having a power factor of 0.4 and time constant of 7 ms (DC). "Electric motor" refers to a load having a value of six times the inrush current.
EN/GB-compliant model ratings (G type, with ground terminal)
Reference rating (Ratings fluctuate according to the operating environment and type of load. Verify values on an actual operating unit.)
UL electrical ratings
Electrical rating Load No. of cycles
1LS1-J
No indicator lamp
Ag
A300 Pilot Duty 6,000
3 A, DC 30 V DC General 6,000
0.4 A, DC 125 V DC General 6,000
Au
0.1 A, AC 125 V AC General 6,000
0.1 A, DC 30 V DC General 6,000
1LS1-JEC
With a neon lamp
Ag A300 Pilot Duty 6,000
Au 0.1 A, AC 125 V AC General 6,000
1LS1-JEC
With an LED
Ag
B150 Pilot Duty 6,000
3 A, DC 30 V DC General 6,000
0.4 A, DC 125 V DC General 6,000
Au
0.1 A, AC 125 V AC General 6,000
0.1 A, DC 30 V DC General 6,000
1LS1-JE7-PD
With an LED (with a connector/connector and cable)
Ag 3 A, DC 30 V DC General 6,000
Au 0.1 A, DC 30 V DC General 6,000
Enclosure: Type 1
Maximum allowable ambient temperature: 40 °C
D-028
LIMIT SWITCHES
WITH POSITIVE
OPENING MECHANISM
GENERAL PURPOSE
LIMIT SWITCHES
TECHNICAL GUIDE
FOR
LIMIT SWITCHES
EXPLOSION-PROOF
SWITCHES
TECHNICAL GUIDE FOR
EXPLOSION-PROOF
SWITCHES
F-001
See page
Connector
with cable
SPATTER-GUARDED
LS
1LS-J7
1LS-J8
VCL-
1LS-J401
SL1-
SL1-C
PHOTOELECTRIC
SENSORS &
SWITCHES
MEASUREMENT
SENSORS
PROXIMITY
SWITCHES
LIMIT
SWITCHES
SAFETY
KEY SWITCHES
STANDARD
LS
LS Series connectors
Catalog listing Name Appearance
Power supply
Number of leads
2 leads 4 leads
LS-PA5A2
LS-PA5A4
LS-PA5D2
LS-PA5D4
2-lead type 4-lead type
AC
DC
Assembly method
PA5 Series
sealed connector
with cable
Models (e.g. 2LS-J, 8LS-J) for which a complete model No. is not given can be modified
into the connector type by attaching the separate parts indicated below to a standard LS Series body.
Wiring method
2-lead type: catalog listing LS-PA52 4-lead type: catalog listing LS-PA54
Connector
Connector
*Even in an N.C. wiring connection, N.C. contact assignments are Nos. 3 and 4.
1
2
3
4
Contact No.
Internal switch
Terminal No.
NO.1
(
N.C.
)
NO.2
(
N.C.
)
NO.3
(
N.O.
)
NO.4
(
N.O.
)
Lead color
Red
Green
Black
White
Contact No.
1
2
3
4
Internal switch
Terminal No.
NO.3
NO.4
Lead color
Black
White
LIFE VS. LOAD CURRENT CHARACTERISTICS
CONNECTORS
Pin layout
3
2
1
4
Black
3
2
1
4
Green
Red
Black White
White
D-029
LIMIT SWITCHES
WITH POSITIVE
OPENING MECHANISM
GENERAL PURPOSE
LIMIT SWITCHES
TECHNICAL GUIDE
FOR
LIMIT SWITCHES
EXPLOSION-PROOF
SWITCHES
TECHNICAL GUIDE FOR
EXPLOSION-PROOF
SWITCHES
SPATTER-GUARDED
LS
1LS-J7
1LS-J8
VCL-
1LS-J401
SL1-
SL1-C
PHOTOELECTRIC
SENSORS &
SWITCHES
MEASUREMENT
SENSORS
PROXIMITY
SWITCHES
LIMIT
SWITCHES
SAFETY
KEY SWITCHES
STANDARD
LS
Assembly method
Wiring method
30 cm 4
Sealed connector
PA5-4IBX03HK4-E
PA5-4JBX03HK4-E
PA1-A10PF
PA5 Series
connector cable
Cable length
Number of leads
Catalog listing Name Appearance Power supply
Standard
LS model
Connector cable,
catalog listing
PA5-4BX03HK4-E
Sealed connector,
catalog listing
PA1-A10PF
Preleaded connector,
type LS
DC
AC
Models (e.g. 2LS-J, 8LS-J) for which a complete model No. is not given can be modified into the preleaded connector type
by attaching the separate parts indicated below to a standard LS Series body.
Preleaded connector for LS Series
D-030
LIMIT SWITCHES
WITH POSITIVE
OPENING MECHANISM
GENERAL PURPOSE
LIMIT SWITCHES
TECHNICAL GUIDE
FOR
LIMIT SWITCHES
EXPLOSION-PROOF
SWITCHES
TECHNICAL GUIDE FOR
EXPLOSION-PROOF
SWITCHES
F-001
See page
Connector
with cable
SPATTER-GUARDED
LS
1LS-J7
1LS-J8
VCL-
1LS-J401
SL1-
SL1-C
PHOTOELECTRIC
SENSORS &
SWITCHES
MEASUREMENT
SENSORS
PROXIMITY
SWITCHES
LIMIT
SWITCHES
SAFETY
KEY SWITCHES
STANDARD
LS