00197569-01_MM_DLM34_Kunde_en.pdf - 第25页

Minor Maintenance 3.1.4 Performing Maintenance Tasks Maintenance Tasks for DLM Maintenance Manual SIPLACE Placement Heads DL M3/DLM4 25 ► Clea n the sleeve sha ft (1) with a lint-free cloth, mois - tened with ethanol. ► …

100%1 / 50
Minor Maintenance
Maintenance Tasks for DLM 3.1.4 Performing Maintenance Tasks
24 Maintenance Manual SIPLACE Placement Heads DLM3/DLM4
Remove the dirt from the longitudinal vacuum hole by
turning the 1.4 mm drill bit clockwise in the hole. Turn
-
ing the bit will remove the dirt from the hole.
Use the same procedure to remove the dirt from the
transverse vacuum hole using the 1.1 mm drill bit.
Wear laboratory gloves for this step.
(1) Check the suction plate for damage. If it is dam
-
aged, replace it.
(2) Clean the sleeve suction plate using a dry, lint-
free cloth.
Clean the edge (1) of the sleeve with a lint-free cloth,
moistened with ethanol.
Clean the incremental disk (2) of the sleeve with a
lint-free cloth, moistened with ethanol.
Minor Maintenance
3.1.4 Performing Maintenance Tasks Maintenance Tasks for DLM
Maintenance Manual SIPLACE Placement Heads DLM3/DLM4 25
Clean the sleeve shaft (1) with a lint-free cloth, mois
-
tened with ethanol.
Carefully clean the circumference (2) of the ball catch
with a cottonwool bud moistened with ethanol.
Minor Maintenance
Maintenance Tasks for Nozzles 3.2.1 Maintenance Intervals
26 Maintenance Manual SIPLACE Placement Heads DLM3/DLM4
3.2
3.2 Maintenance Tasks for Nozzles
Maintenance Tasks for Nozzles
3.2.1
3.2.1 Maintenance Intervals
Maintenance Intervals
3000 - Minor - Nozzles
3.2.2
3.2.2 Tools, Consumables, Spare and Wear Parts
Tools, Consumables, Spare and Wear Parts
NOTICE
Example
The following tasks are described using the example of a CPP nozzle magazine. The procedure
is the same for other nozzle magazines. Any relevant differences will be mentioned explicitly.
Make sure that you use the correct cleaning boxes for your nozzles.
Maintenance tasks
Nozzles
Duration
[min]
Each
week
Every 3
months
Every 6
months
Every 12
months
Cleaning/Replacing the Ceramic Nozzles 2 X
Replacing the Plastic Nozzles 2 X
Consumables Item no. HMK
SIPLACE recommends that you use the following cleaning fluids from
ZESTRON (http://www.zestron.com):
VIGON SC 200
Compressed air
Distilled water
Tools Item no. HMK
ESD wriststrap 00320279- xx
SIPLACE recommends that you use the following ultrasound device and
accessory parts from BANDELIN electronic (http://www.bandelin.com):
Ultrasound device SONOREX SUPER RK 510 [order no. Bandelin:
327]
Clip-on basket K 10 [order no. Bandelin: 359]
Handle adjustment GV 10 for baskets (1 pair) [order no. Bandelin: 092]
Lid D 510 [order no. Bandelin: 3008]
Nozzles 10xx, 12xx, 20xx, 28xx, 40xx According to
configuration
Ceramic nozzles 10xx, 12xx, 20xx, 28xx, 40xx According to
configuration
If required, nozzle magazine type 40xx (for C&P20 P)
(Replaces: magazine assembly C&P20 [03016831-xx])
03101503- xx
If required, nozzle magazine type 20xx (depending on configuration) 03066107- xx
Plastic brush Dm 8 00325866- xx
For C&P20/A/M/P and CPP
Guiding plate long for 10xx/20xx
Note: When using ceramic nozzles for the CPP, you need the guide
plate with function state 02.
03066508- xx
Cleaning box for ceramic nozzles, type 20xx/long (for CPP) 03076627- xx
Cleaning box ceramic nozzles type 10xx/long (for C&P20/A/M) 03055736- xx
Cleaning box ceramic nozzles type 40xx/long (for C&P20 P) 03107651- xx
Cleaning rack 10xx (for C&P20/A/M and CPP), if required 03071700- xx