00197569-01_MM_DLM34_Kunde_en.pdf - 第25页
Minor Maintenance 3.1.4 Performing Maintenance Tasks Maintenance Tasks for DLM Maintenance Manual SIPLACE Placement Heads DL M3/DLM4 25 ► Clea n the sleeve sha ft (1) with a lint-free cloth, mois - tened with ethanol. ► …

Minor Maintenance
Maintenance Tasks for DLM 3.1.4 Performing Maintenance Tasks
24 Maintenance Manual SIPLACE Placement Heads DLM3/DLM4
► Remove the dirt from the longitudinal vacuum hole by
turning the 1.4 mm drill bit clockwise in the hole. Turn
-
ing the bit will remove the dirt from the hole.
► Use the same procedure to remove the dirt from the
transverse vacuum hole using the 1.1 mm drill bit.
► Wear laboratory gloves for this step.
► (1) Check the suction plate for damage. If it is dam
-
aged, replace it.
► (2) Clean the sleeve suction plate using a dry, lint-
free cloth.
► Clean the edge (1) of the sleeve with a lint-free cloth,
moistened with ethanol.
► Clean the incremental disk (2) of the sleeve with a
lint-free cloth, moistened with ethanol.

Minor Maintenance
3.1.4 Performing Maintenance Tasks Maintenance Tasks for DLM
Maintenance Manual SIPLACE Placement Heads DLM3/DLM4 25
► Clean the sleeve shaft (1) with a lint-free cloth, mois
-
tened with ethanol.
► Carefully clean the circumference (2) of the ball catch
with a cottonwool bud moistened with ethanol.

Minor Maintenance
Maintenance Tasks for Nozzles 3.2.1 Maintenance Intervals
26 Maintenance Manual SIPLACE Placement Heads DLM3/DLM4
3.2
3.2 Maintenance Tasks for Nozzles
Maintenance Tasks for Nozzles
3.2.1
3.2.1 Maintenance Intervals
Maintenance Intervals
3000 - Minor - Nozzles
3.2.2
3.2.2 Tools, Consumables, Spare and Wear Parts
Tools, Consumables, Spare and Wear Parts
NOTICE
Example
The following tasks are described using the example of a CPP nozzle magazine. The procedure
is the same for other nozzle magazines. Any relevant differences will be mentioned explicitly.
► Make sure that you use the correct cleaning boxes for your nozzles.
Maintenance tasks
Nozzles
Duration
[min]
Each
week
Every 3
months
Every 6
months
Every 12
months
Cleaning/Replacing the Ceramic Nozzles 2 X
Replacing the Plastic Nozzles 2 X
Consumables Item no. HMK
SIPLACE recommends that you use the following cleaning fluids from
ZESTRON (http://www.zestron.com):
▪ VIGON SC 200
Compressed air
Distilled water
Tools Item no. HMK
ESD wriststrap 00320279- xx
SIPLACE recommends that you use the following ultrasound device and
accessory parts from BANDELIN electronic (http://www.bandelin.com):
▪ Ultrasound device SONOREX SUPER RK 510 [order no. Bandelin:
327]
▪ Clip-on basket K 10 [order no. Bandelin: 359]
▪ Handle adjustment GV 10 for baskets (1 pair) [order no. Bandelin: 092]
▪ Lid D 510 [order no. Bandelin: 3008]
Nozzles 10xx, 12xx, 20xx, 28xx, 40xx According to
configuration
Ceramic nozzles 10xx, 12xx, 20xx, 28xx, 40xx According to
configuration
If required, nozzle magazine type 40xx (for C&P20 P)
(Replaces: magazine assembly C&P20 [03016831-xx])
03101503- xx
If required, nozzle magazine type 20xx (depending on configuration) 03066107- xx
Plastic brush Dm 8 00325866- xx
For C&P20/A/M/P and CPP
Guiding plate long for 10xx/20xx
► Note: When using ceramic nozzles for the CPP, you need the guide
plate with function state 02.
03066508- xx
Cleaning box for ceramic nozzles, type 20xx/long (for CPP) 03076627- xx
Cleaning box ceramic nozzles type 10xx/long (for C&P20/A/M) 03055736- xx
Cleaning box ceramic nozzles type 40xx/long (for C&P20 P) 03107651- xx
Cleaning rack 10xx (for C&P20/A/M and CPP), if required 03071700- xx