Minor Maintenance
Maintenance Tasks for Nozzles 3.2.5 Performing Maintenance Tasks
30 Maintenance Manual SIPLACE Placement Heads DLM3/DLM4
Pull off the cleaning box, together with the nozzles.
Place an empty cleaning box into the ultrasonic bath.
Fill the ultrasound bath with cleaning fluid until the
cleaning boxes are covered with a layer about 1 mm
deep.
NOTICE!
All cleaning boxes have the same height. It therefore
does not matter which cleaning box you use to test the fill
-
ing level.
Place the cleaning box with the nozzles onto an emp
-
ty cleaning box.
Place the cleaning boxes with the nozzle tips facing
downwards into the ultrasonic bath. Also observe the
following instructions:
Minor Maintenance
3.2.5 Performing Maintenance Tasks Maintenance Tasks for Nozzles
Maintenance Manual SIPLACE Placement Heads DLM3/DLM4 31
NOTICE
Cleaning the nozzles
The fluid level should not exceed or undershoot the prescribed height by more than 2 mm
as this could impair the cleaning effect.
Only the ceramic tips may come into continuous contact with the cleaning fluid. These
should reach into the fluid by approx. 2 mm.
Make sure that the nozzle tips do not come into contact with the cleaning vessel or other
metal parts.
Make sure that the plastic parts of the nozzle do not come into contact with the cleaning
fluid.
The nozzle magazines may not be placed into the cleaning fluid.
The recommended cleaning time for normal levels of nozzle dirt is 10 to 15 min. This time
may vary, depending on the type of dirt.
At the end of the cleaning time, take the cleaning box
out of the ultrasonic bath.
Turn the cleaning box so that the nozzle tips face up
-
wards.
Place the guidance for the plastic brush into the
cleaning box.
Minor Maintenance
Maintenance Tasks for Nozzles 3.2.5 Performing Maintenance Tasks
32 Maintenance Manual SIPLACE Placement Heads DLM3/DLM4
Apply slight pressure and move the brush back and
forth to remove the partially dissolved dirt and resi
-
dues.
Check the cleaning result with a magnifying glass or
microscope.
(1) Remove the brush guidance.
Place the nozzles in the nozzle magazine and close
the slide (2).
Dry the nozzles with compressed air.
If you are using nozzles with a nozzle ID (1), vacuum
the nozzle shaft (dust, components).
If you are unable to clean here, replace the nozzle.
Place the nozzle magazine back in the nozzle chang
-
er.
CAUTION!
Reinsert the nozzle magazine into the same position in
the nozzle changer as before (when it was removed be
-
fore cleaning).