12 Extraction Control via the Pedal Th e fu me ex tr actor a sp irat ion c an b e ac tivate d/dea cti vated by u sin g JBC’s peda l P405 or P0 0 5. Pedal Connection Co nne ct th e pe da l to the pe da l co nn ec tor an d…

100%1 / 20
11
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - color gris
200 mm
300 mm
Port
Parameter Description
Program
It sets the fume extractor aspiration flow. You can select between preset
and custom aspiration programs.
H (High), M (Medium) or L (Low) are the three available preset options.
Use UP and DOWN keys to switch between them while being on the main
screen.
Up to ten aspiration levels between H (High) and L (Low) can be selected
for custom program (range 10-100%). If a custom aspiration program is
selected, the selected aspiration level can be changed on the main screen.
By default, M (Medium) aspiration program is selected.
Delay to stop /
Stand
It sets the time that a fume extractor keeps aspirating fumes at the stand
once the tool is returned to it (range 0-999 seconds)
By default stand time is 60 seconds.
Delay to stop /
Work area
It sets the time that a fume extractor keeps aspirating fumes at the work
area once the tool is returned to the stand (range 0-300 seconds).
Pedal / Activation
It sets the pedal activation mode. There are two different modes: “pressed”
and “released”.
One-touch: Press the pedal once to activate aspiration. Press again to
stop aspiration.
Pressed: (Mode function must be pressed) aspiration is active as long as
the pedal is kept pressed.
By default activation is pressed.
Pedal / Mode
When the activation parameter is set to pressed, the mode parameter can
be configured to released mode. In this mode aspiration is always active
until the pedal is pressed.
By default mode is pressed.
12
Extraction Control via the Pedal
The fume extractor aspiration can be activated/deactivated by using JBC’s pedal P405 or P005.
Pedal Connection
Connect the pedal to the pedal connector and read the description for “Pedal / Activation” and
“Pedal/Mode” on the previous page.
Filter Set
Parameter Description
Carbon life
It shows remaining activated carbon lifetime expressed in %. It is also dis-
played on the main screen. When 0% is reached the system will show pop-
up message STOP#1 to replace the filter.
Saturation
It shows saturation status of HEPA + carbon filter set, expressed in %. It is
also displayed on the main screen. When 100% is reached the system will
show pop-up message STOP#2 to replace the filter.
Reset carbon
Perform this action after replacing the HEPA + carbon filter set. The carbon
lifetime counter will not start until the filter is detected for the first time. After
executing that function carbon filter life will be 100%.
P405 Pedal
or
P005 Pedal
13
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - color gris
200 mm
300 mm
Fume Extractor Configurations
Some parameters, features and the performance vary depending on fume extractor configuration,
see the following table:
230V - 50/60Hz Mode: 1 Workbench Mode: 2 Workbenches
Flexible Arm Aspiration Intake
1 2
Stand Aspiration Intake 1 Not available
Flow per Flexible Arm Intake 80 m
3
/ h (47.08 cfm) 80 m
3
/h (47.08 cfm)
Preset Aspiration Programs 3 3
Custom Aspiration Programs 10 10
Power Consumption 130 W 300 W
120V - 50/60Hz Mode: 1 Workbench Mode: 2 Workbenches
Flexible Arm Aspiration Intake
1 2
Stand Aspiration Intake 1 Not available
Flow per Flexible Arm Intake 80 m
3
/ h (47.08 cfm) 75 m
3
/h (44.14 cfm)
Preset Aspiration Programs 3 3
Custom Aspiration Programs 10 10
Power Consumption 135 W 270 W
100V - 50/60Hz Mode: 1 Workbench Mode: 2 Workbenches
Flexible Arm Aspiration Intake
1 2
Stand Aspiration Intake 1 Not available
Flow per Flexible Arm Intake 80 m
3
/h (47.08 cfm) 65 m
3
/h (38.28 cfm)
Preset Aspiration Programs 3 3
Custom Aspiration Programs 10 10
Power Consumption 135 W 200 W