DECAN_S1_Maintenance(Eng_Ver1.1)_Print.pdf - 第56页
Mon thly Inspe ction chapt er 5 Nex t Generation, Multi- Functi onal Placer DE CAN S1 M ain ten anc e Ha nd boo k 5-1 Cleaning Head Spindle T ool for M aintenanc e Cleaning liquid, ultra fine fiber cloth, air gun Measure…

Weekly Inspection
chapter 4
Next Generation, Multi-Functional Placer
DECAN S1 Maintenance Handbook
4-6
Checking and Replacing Head Vacuum Filter
Weekly Inspection
Step 5.
Remove by turning in the direction of the arrow Vacuum
Filter.
Step 6.
Release the emergency stop as described in "Releasing
'Emergency Stop' mode" on page 1-6 and perform the
operation again.
Caution
Check the vacuum filter every week and replace it within at least 6
months to ensure the vacuum for part pickup is generated properly.
Caution
As the Solenoid Valve is a consumable, it is recommended to
replace it every two years for stable operation.
If you need to replace the Solenoid Valve, please contact your local
dealership for action.
Dispose of contaminated filters removed from the equipment
immediately as they cannot be reused and improper use may cause
problems with product performance.

Monthly Inspection
chapter 5
Next Generation, Multi-Functional Placer
DECAN S1 Maintenance Handbook
5-1
Cleaning Head Spindle
Tool for Maintenance
Cleaning liquid, ultra fine fiber cloth, air gun
Measures
Step 1.
Move the X Frame to front by referring to "Forward
movement of the X-frame" on page 1-3
Step 2.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to "How to perform emergency stop" on page
1-2.
Step 3.
Saparate the coil tube from vacuum filter
chapter 5
Monthly Inspection
Step 4.
Remove the nozzle
Cleaning Head Spindle
(Time required: 30min / No. M-1)

Monthly Inspection
chapter 5
Next Generation, Multi-Functional Placer
DECAN S1 Maintenance Handbook
5-2
Cleaning Head Spindle
Monthly Inspection
Step 5.
Put the cloth underneath the spindle
Step 6.
Cleaning the interior of the tube by an air gun.
Caution
Using the air gun without putting on goggles may cause injury to
operator's eyes. Be sure to wear goggles when using the air gun.
Step 7.
Release the emergency stop as described in "Releasing
'Emergency Stop' mode" on page 1-6 and perform the
operation again.