Mon thly Inspe ction chapt er 5 Nex t Generation, Multi- Functi onal Placer DE CAN S1 M ain ten anc e Ha nd boo k 5-8 Checking and Cleaning Control Rack Cooling F an Monthly Inspe ction Step 4 . T ur n on th e main sw it…

Monthly Inspection
chapter 5
Next Generation, Multi-Functional Placer
DECAN S1 Maintenance Handbook
5-7
Checking and Cleaning Control Rack Cooling Fan
Tool for Maintenance
Wrech, vacuum cleaner, screwdriver
Measures
Step 1.
Turn off the power supply to the machine as described
ino "How to turn off the power supply" on page 1-1.
Step 2.
Remove the front cover of the machine using a
crosshead screwdriver.
Checking and Cleaning Control Rack Cooling Fan
Step 3.
Clean the internal fan of the control rack assembly with
a vacuum cleaner.
(Time required: 10min / No. M-6)

Monthly Inspection
chapter 5
Next Generation, Multi-Functional Placer
DECAN S1 Maintenance Handbook
5-8
Checking and Cleaning Control Rack Cooling Fan
Monthly Inspection
Step 4.
Turn on the main switch after cleaning.
If the cooling fan generates noise and operates abnormally, turn off
the main switch of the machine and replace it.
Caution
Since the replacement of the cooling fan accompanies a danger,
contact our C/S Company or local agent when replacing a cooling
fan.
Caution
A hand may get injured by the cooling fan when turning on the
main switch of the machine, and touching the cable, etc. may cause
electric shock. Therefore, special care must be exercised.

Monthly Inspection
chapter 5
Next Generation, Multi-Functional Placer
DECAN S1 Maintenance Handbook
5-9
Cleaning and Lubricating Head Spindle, Mirror CAM
Tool for Maintenance
Ultra-fine fiber cloth, Flat Brush, syringe, GREASE GADUS S2 V220-2
Measures
Step 1.
Move the X Frame to front by referring to "Forward
movement of the X-frame" on page 1-3.
Step 2.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to "How to perform emergency stop" on page
1-2.
Step 3.
Clean the LM guide rail, ball screw and mirror CAM
Cleaning and Lubricating Head Spindle, Mirror CAM
(Time required: 30min / No. M-7)