31 Technical data Electrical ratings, energy consumption and compressed air supply 1 = Electrical connection 2 = Compressed air connection The connections are run into the machine from below a nd then co nnected to t he …

100%1 / 46
30
Technical data
Electrical ratings, energy consumption and
compressed air supply
Electrical ratings
Supply voltage
Main power supply 3 x 380 V~ to 3 x 415 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 220 V~ ± 10 %; 50/60 Hz
a
a) With options package
3 x 16A characteristic C
3 x 15A characteristic C
b
b) e.g. Siemens circuit breakers in accordance with IEC and UL 489 (order no.: 5SJ4 316-7HG42)
or
EATON Industries circuit breaker FAZ-C16/3-NA 16A 3p (UL 489, CSA C22.2 no. 5, IEC 60947-2)
Mains power connec-
tion
Without cable
Cable 5 x 2.5 mm² WITH CEE plug, red 16 A (in accordance with IEC 60309)
(3 x 380 V~ to 3 x 415 V~)
Cable 5 x 2.5 mm² WITHOUT plug (3 x 200 V~ to 3 x 220 V) or (3 x 380 V~ to 3 x 415 V~)
Short circuit rating (SCCR)
c
c) With the original mains connection cable. The marked short circuit rating (SCCR) relates to the beginning of the original
mains cable. In the case of customer modifications, the factory-set length of the mains cable to the placement machine
may not be shortened nor the factory-set conductor cross-section increased, as this would have a negative impact on
the short circuit rating (SCCR).
10 kA
Energy consumption
With a vacuum pump
d
d) Vacuum pump for C&P20 M2 head only. The vacuum pump is not approved for clean room ISO class 7 and must be
operated in the gray room.
Without a vacuum pump
Nominal apparent
power
2.6 kVA 2.3 kVA
Nominal active power 2.00 kW 1.2 kW
Compressed air supply
Compressed air pres-
sure values
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air con-
nection
1/2" hose connection
Compressed air consumption
e
e) Average consumption values. Under normal atmospheric conditions at 20°C and 1013 hPa.
Placement head configuration Compressed air
consumption
with a vacuum pump
b
Compressed air consumption
without vacuum pump
SIPLACE TX micron C&P20 M2/C&P20 M2
CPP M/CPP M
120 Nl/min
No option
500 Nl/min
360 Nl/min
Compressed air specification according to ISO 8573
Particle size (ISO class 3) 0.1 µm
Particle density (ISO class 3) 0.1 mg/m³
Maximum oil content (ISO class 1) Particle density 0.01 mg/m³
Pressure dewpoint (ISO class 4) Dewpoint + 3°
PLEASE NOTE:
Also observe the document "Network and compressed air configuration for SMD systems" (German+English,
item no. 00197548-xx), which is supplied with your SIPLACE machine.
31
Technical data
Electrical ratings, energy consumption and
compressed air supply
1 = Electrical connection
2 = Compressed air connection
The connections are run into the machine from below and then connected to the power supply
or pneumatic unit terminals.
32
Technical data
Dimensions and setup conditions
Length
a
Without conveyor extension and with hand guard
With input conveyor extension
b
With output conveyor extension
With input and output conveyor extension)
a) Measured at the outer contour of the machine protection.
b) Only at the first machine in the line.
1000 mm
1260 mm
1604 mm
1864 mm
Width
Outer contour of machine protection (table "inside")
With monitor
Outer contour of machine protection (table location 1 "outside")
Machine frame
2232 mm
2386 mm
2324 mm
2048 mm
Height of machine (for PCB conveyor height 950 mm)
Up to upper edge of machine protection
With 2-color indicator lamp
With 3-color indicator lamp
Without indicator lamp (height of packaging)
With folded-up short protective cover 45 degrees position
With folded-up short protective cover 60 degrees position
With folded-up short protective cover 45 degrees position
With folded-up short protective cover 60 degrees position
1500 mm
1690 mm
1735 mm
1500 mm
1960 mm
2070 mm
2050 mm
2175 mm
Machine ground clearance
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
120 mm ± 15 mm
150 mm ± 15 mm
170 mm ± 15 mm
Weight
SIPLACE TX micron (machine with component trolley)
SIPLACE TX micron (fully equipped with feeder modules)
2050 kg
2150 kg
Location
c
With tables, outside
c) Measured at the outer contour of the machine protection and without conveyor extension.
2.23 m²
2.33 m²
Even surface load
Characteristic surface load
6.75 kN/m²
7.70 kN/m²
Number of machine feet 4
Max. noise emissions 75 dB (A)
Room temperature Between
+18°C and +25°C (± 2K)
Atmospheric humidity 30% to 75 % (no higher than 45% on
average to prevent any possibility of con-
densation on the machine)