CP40 service manual.pdf - 第29页
MODULE ERROR CODE Symptom and Cause ACTION Service Manual $8351 Nozzle Run-out check error (Run-out>0.120mm) (Head 1) Run-out of nozzle exceeds 0.12mm. This has an effect on align check and installment accuracy. $8352…

MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$8271
Object size caliper error (Head 1)
Fails to receive the object size measurement command caused by communication
error.
7-3-1
$8272
Object size caliper error (Head 2)
Fails to receive the object size measurement command caused by communication
error.
$8273
Object size caliper error (Head 3)
Fails to receive the object size measurement command caused by communication
error.
$8311
Nozzle find Error (Head 1)
Communication error occurs when Z-axis finds out Align height of Nozzle.
$8312
Nozzle find Error (Head 2)
Communication error occurs when Z-axis finds out Align height of Nozzle.
$8313
Nozzle find Error (Head 3)
Communication error occurs when Z-axis finds out Align height of Nozzle.
$8321
Nozzle Inspection Error (Head 1)
Communication error occurs when θ-axis inspects run-out of nozzle.
$8322
Nozzle Inspection Error (Head 2)
Communication error occurs when θ-axis inspects run-out of nozzle.
$8323
Nozzle Inspection Error (Head 3)
Communication error occurs when θ-axis inspects run-out of nozzle.
$8331
Nozzle Inspection Result Error (Head 1)
Communication error occurs when θ-axis inspects run-out of nozzle.
$8332
Nozzle Inspection Result Error (Head 2)
Communication error occurs when θ-axis inspects run-out of nozzle.
$8333
Nozzle Inspection Result Error (Head 3)
Communication error occurs when θ-axis inspects run-out of nozzle.
$8341
Nozzle Check Error. Please check Nozzle. (Head 1)
Occurs when nozzle exists actually in head however program indicates no nozzle
exists in the head.
4-3-2
$8342
Nozzle Check Error. Please check Nozzle. (Head 2)
Occurs when nozzle exists actually in head however program indicates no nozzle
exists in the head.
4-3-4
Woori Align
Part
$8343
Nozzle Check Error. Please check Nozzle. (Head 3)
Occurs when nozzle exists actually in head however program indicates no nozzle
exists in the head.
Check for abnormal conditions of Nozzle data in dialog box displayed after executing the command
of <Setup/ANC Setting> in MMI.
4-3-2
4-3-4
Try again after finding out again Home position by turning on the Aligner DSP Board by pressing and
releasing the <Emergency> switch of operation panel or teaching box.
Check for cable linked conditions between Aligner DSP Board and VME RS-232C I/F Board.
Check for abnormal conditions of Nozzle data in dialog box displayed after executing the command
of <Setup/ANC Setting> in MMI.
- 15 -

MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$8351
Nozzle Run-out check error (Run-out>0.120mm) (Head 1)
Run-out of nozzle exceeds 0.12mm.
This has an effect on align check and installment accuracy.
$8352
Nozzle Run-out check error (Run-out>0.120mm) (Head 1)
Run-out of nozzle exceeds 0.12mm.
This has an effect on align check and installment accuracy.
12-3-2
$8353
Nozzle Run-out check error (Run-out>0.120mm) (Head 1)
Run-out of nozzle exceeds 0.12mm.
This has an effect on align check and installment accuracy.
$8701
Aligner result response Error (Head 1)
Fails to receive align results caused by communication error.
$8702
Aligner result response Error (Head 2)
Fails to receive align results caused by communication error.
1-3-1
$8703
Aligner result response Error (Head 3)
Fails to receive align results caused by communication error.
7-3-1
$8711
Aligner Score is too low (Head 1)
Fails to algin during retrying times.
(Either align score of X and Y is less than 80).
$8712
Aligner Score is too low (Head 2)
Fails to algin during retrying times.
(Either align score of X and Y is less than 80).
$8713
Aligner Score is too low (Head 3)
Fails to algin during retrying times.
(Either align score of X and Y is less than 80).
$8731
Aligner component auto inspection error (Head 1)
Fails to find out align information automatically.
12-3-1
$8732
Aligner component auto inspection error (Head 2)
Fails to find out align information automatically.
12-3-3
$8733
Aligner component auto inspection error (Head 3)
Fails to find out align information automatically.
$8741
Please check nozzle in the Head (Head 1)
Nozzle fails to be inserted securely into Head securely.
4-3-2
$8742
Please check nozzle in the Head (Head 2)
Nozzle fails to be inserted securely into Head securely.
4-3-4
Nozzle is to be inserted securely into a Head.
Try again after finding out again Home position by turning on the Aligner DSP Board by pressing and
releasing the <Emergency> switch of operation panel or teaching box.
Check for cable linked conditions between Aligner DSP Board and VME RS-232C I/F Board.
Try again by pressing the Start switch after removing the error condition by pressing the <Reset>
switch of operation panel.
Check that part concerned exists in feeder, and for pickup conditions of part.
Replace a Compliance of Head concerned. (Recommendations)
- 16 -

MODULE
ERROR
CODE
Symptom and Cause ACTION
Service
Manual
$8743
Please check nozzle in the Head (Head 3)
Nozzle fails to be inserted securely into Head securely.
$8821
Aligner Received Unknown Command From Host[02] (Head 1)
Aligner DSP Board is received unknown command from Host(Component Placer).
$8822
Aligner Received Unknown Command From Host[02] (Head 2)
Aligner DSP Board is received unknown command from Host(Component Placer)
1-3-1
$8823
Aligner Received Unknown Command From Host[02] (Head 3)
Aligner DSP Board is received unknown command from Host(Component Placer).
7-3-1
$8831
Aligner Sent Unknown Command From Host[03] (Head 1)
Host(Component Placer) sent unknown command to Aligner DSP Board.
$8832
Aligner Sent Unknown Command From Host[03] (Head 2)
Occurs when Host(Component Placer) transfers unknown command to Aligner DSP
Board.
Woori Align
Part
$8833
Aligner Sent Unknown Command From Host[03] (Head 3)
Occurs when Host(Component Placer) transfers unknown command to Aligner DSP
Board.
Try again after finding out again Home position by turning on the Aligner DSP Board by pressing and
releasing the <Emergency> switch of operation panel or teaching box.
Check for cable linked conditions between Aligner DSP Board and VME RS-232C I/F Board.
1-3-1
7-3-1
$8841
Aligner received zero length message[04] (Head 1)
Occurs when Aligner DSP Board receives incorrect data from Host(Component
Placer).
1-3-1
$8842
Aligner received zero length message[04] (Head 2)
Occurs when Aligner DSP Board receives incorrect data from Host(Component
Placer).
7-3-1
$8843
Aligner received zero length message[04] (Head 3)
Occurs when Aligner DSP Board receives incorrect data from Host(Component
Placer).
$8851
Aligner failed to write to Host[05] (Head 1)
Occurs when Aligner DSP Board can not respond to Host(Component Placer).
$8852
Aligner failed to write to Host[05] (Head 2)
Occurs when Aligner DSP Board can not respond to Host(Component Placer).
$8853
Aligner failed to write to Host[05] (Head 3)
Occurs when Aligner DSP Board can not respond to Host(Component Placer).
1-3-1
$8861
Aligner failed to read from Host[06] (Head 1)
Occurs when Aligner DSP Board can not receive data from Host(Component
Placer).
1-3-3
$8862
Aligner failed to read from Host[06] (Head 2)
Occurs when Aligner DSP Board can not receive data from Host(Component
Placer).
$8863
Aligner failed to read from Host[06] (Head 3)
Occurs when Aligner DSP Board can not receive data from Host(Component
Placer).
Try again after finding out again Home position by turning on the Aligner DSP Board by pressing and
releasing the <Emergency> switch of operation panel or teaching box.
Check for cable linked conditions between Aligner DSP Board and VME RS-232C I/F Board.
Try again after finding out again Home position by turning on the Aligner DSP Board by pressing and
releasing the <Emergency> switch of operation panel or teaching box.
Check for cable linked conditions between Aligner DSP Board and VME RS-232C I/F Board.
- 17 -