Product Engineering Division SMT Sect ion IM Operations Y AMAHA MOTOR CO., L TD MDOC-SOFT 5 0038-001 10/15 7 Appe ndix 7.1 A utoma tic se ttings The work of this chapter is not nec essary unless line c onstitution is c h…

100%1 / 15
Product Engineering Division
SMT Section
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50038-001 9/15
6 Limitation
Please note that this function has the following limitations.
This function does not work other than “ADVANCED_GATE".
Only when the “ADVANCED GATE 2” is used as the transfer signal cable, this function
becomes effective. When this function is used other than “ADVANCED GATE 2” as the
transfer signal cable, interlock errors etc. occur, and normal operation cannot be done.
When this machine is with the buffer conveyor (include d-YTF) in the downstream side,
“Stride Board Buffering” function is not available in the downstream side.
Product Engineering Division
SMT Section
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50038-001 10/15
7 Appendix
7.1 Automatic settings
The work of this chapter is not necessary unless line constitution is changed.
The following setting is necessary when line constitution is changed or when upstream /
downstream machine is changed. However, the mechanical change of the conveyor in
upstream machine or this machine or downstream machine exists, please refer to "Chapter.7.2.
Manual Settings".
Please tap on [VmSpec] – [Toolbar] – [Stride Board Buffering Setting] button (See Fig.7.1).
When it is taped, [Stride Board Buffering Setting] screen opens.
Fig.7.1 VmSpec Screen
Product Engineering Division
SMT Section
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50038-001 11/15
Fig7.2 Stride Board Buffering Setting
Please set it in the following procedures with [Stride Board Buffering Setting] screen (See
Fig.7.2).
1. Set “Enable” on [Stride Board Buffering Lower] and [Stride Board Buffering Upper] comb
box.
The following settings are set on [Setting] - [Installation Setting] - [Software].
1) [Stride Board Buffering(Upper)] or [Stride Board Buffering(Lower)] is set to “Enable”.
2) [Upper Handling] or [Lower Handling] is set to “ADVANCED GATE”.
2. Set the settings on [Lower Machine Type], [Own Machine Type] and [Upper Machine Type].
Please choose the downstream machine, this machine, upstream machine from the combo
box. The following settings at [Machine data] - [Mechanical] - [Position] - [Stride Board
Buffering] are set
1) [Upper Machine Max Board Size]
2) [Lower Machine Min Board Size]
3) [Lower Machine Max Board Size]
When the machine type that you want to choose is not displayed at the combo box, please
set “Disable” on [Stride Board Buffering –Lower] or [Stride Board Buffering – Upper].
1
1
2
2
2