D) About the display of Enable or Disable state of this function [01]
The Enable / Disable state of this function in the current production is displayed on [Unit] –
[Conveyor] screen (cf. figure.3.2).
Fig.3.2 [Unit]–[Conveyor] screen
Product Engineering Division
SMT Section
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50038-001 6/15
4 Setting
4.1 Machine Setting
From this version, the following settings are added on [Machine Information] - [Installation
Setting] - [Software] (See Fig.4.1). When you do not use this function, please set “Disable” on
the following red frame settings.
1. [Stride Board Buffering(Upper)]
2. [Stride Board Buffering(Lower)]
Fig.4.1 Installation Setting screen
This function can be set individually in upstream (Upper) side and downstream(Lower) side, so
please set “Enable” / “Disable” as needed. Factory default setting is “Disable”.
Product Engineering Division
SMT Section
IM Operations
YAMAHA MOTOR CO., LTD
MDOC-SOFT50038-001 7/15
5 Error Massage
The below is error massages added for this function.
No. Title Cause and Solution
2201
BOARD TRANSFER ERROR
Unexpected Board is on the conveyor.
On the auto-running or the transfer, two
boards are detected at the same time.
When the stopper of the mount position
is going to rise during sync transfer, this
error occurs when the next board
arrives at the mount position.
Please move the boards to the
transfer destination position and
restart auto-running.
When this error occurs many times,
please input a value bigger than the
present value on the machine setting
[Setting] – [Mechanical] – [Position]
– [Fast Trans Delay Timer] (note 1).
3976
WARNING : Stride Board Buffering
Upper Setting
The setting of "Upper Handling" is not
"ADVANCED_GATE" though the setting
of "Stride Board Buffering(Upper)" is
"Enable".
It needs to be set "ADVANCED_GATE"
so that "Stride Board Buffering(Upper)"
works effectively.
Please confirm the settings are set
as follows.
1. [Setting] - [Installation Setting] -
[Upper Handling] :
ADVANCED_GATE
2. [Setting] - [Installation Setting] -
[Stride Board Buffering(Upper)] :
Enable
3977
WARNING : Stride Board Buffering
Lower Setting
The setting of "Lower Handling" is not
"ADVANCED_GATE" though the setting
of "Stride Board Buffering(Lower)" is
"Enable".
It needs to be set "ADVANCED_GATE"
so that "Stride Board Buffering(Upper)"
works effectively.
Please confirm the settings are set
as follows.
1. [Setting] - [Installation Setting] -
[Lower Handling] :
ADVANCED_GATE
2. [Setting] - [Installation Setting] -
[Stride Board Buffering(Lower)] :
Enable
7366
Unknown board is detected at the
wait position sensor
Unknown board is detected at the wait
position sensor.
The board exists though the wait
positions stopper does not rise.
Please remove the board on the wait
position, and restart auto-running.
Please insert the board into the wait
position again after a board in the
machine is carried out.
7337 BOARD TRANSFER ERROR
The board transfer to lower machine
was failed.
The board may be caught between
machines.
Please move the board to the board
fixing position of the downstream
machine, and start auto-running.