6 5. SET-UP INSTRU CTIONS Mechanical Mo unting: Normally, the TS5000DMP-DCX Series valve is used on an automated XYZ table, with full motion control in the three planes. It is very important that the valve i s mounted on…

12
12. TROUBLE SHOOTING
PROBLEM POSSIBLE CAUSE CORRECTION
No Fluid Flow
Dispense tip is plugged Replace tip
Motor does not receive signal
Make sure all connections are
secured
Motor running in reverse
Reverse motor cable
connection
Syringe barrel of dispense fluid
is empty
Replace with new syringe
barrel, of fluid
Fluid feed pressure is too low Increase feed pressure.
Inconsistent
Fluid Flow
Feed screw damaged
Replace with new feed
screw/chamber
Fluid pressure fluctuating
Make sure fluid pressure is
constant
Valve on time is too short Increase valve on time
Excessive motor reverse time
Reduce reverse time or turn
off completely.
Fluid drools after
the valve turned
off
Air trapped in fluid housing Purge valve properly
Dispense tip
clogged
Air trapped in feed screw
chamber
Purge valve properly
Air trapped in fluid reservoir Remove air from reservoir
Excessive fluid feed pressure
Reduce pressure or turn off
pressure when the valve is
idle.
Tip contacting substrate Increase dispense height
5
4. THEORY OF OPERATION (refer to figure 1.0)
The TS5000DMP-DCX Series Rotary Microvalve dispenses fluid with a positive
displacement action using a rotary feed screw principle. Fluid is held in a feed
reservoir (2), normally a syringe barrel or cartridge, under a positive head of air,
between 1 to 20 psi (0.07 to 1.38bar), depending upon the viscosity of the fluid.
The positive air pressure, supplied by the air line (1), forces the fluid out of the
syringe barrel (2) into the material feed path (3) then to the feed screw chamber
(5). Fluid flows from this point (5) to the dispense point (4) and is controlled by
the feed screw rotation in the feed direction. The feed screw is driven by the DC
motor (6). Applying a DC voltage signal to the DC motor (6), will rotate the feed
screw and the fluid will be forced out the dispense tip (4). The actual fluid
deposited is dependent upon adhesion of the dispensed fluid to the substrate.
Shearing of the fluid is achieved by reverse Z-motion (tip retraction). When the
motor stops, the unit remains in position for a fraction of a second (dwell) to allow
the last drop of fluid to flow out of the dispense tip. After the dwell period, the
automation equipment moves the TS5000DMP-DCX valve to the next position.
Figure 1.0

6
5. SET-UP INSTRUCTIONS
Mechanical Mounting:
Normally, the TS5000DMP-DCX Series valve is used on an automated XYZ table,
with full motion control in the three planes. It is very important that the valve is
mounted on the Z-axis gantry, in a secure manner, that will not allow loosening
during dispense operation. The Z-axis must move in a precise and repeatable
motion for successful dispensing.
The provided mounting bracket, or customer supplied bracket, must be attached to
the Z-axis in a manner that will provide the valve perpendicular travel to the
horizontal plane of the surface on which the fluid will be dispensed. The mounting
should provide a means of accurately adjusting the distance between the dispense
tip and the substrate surface such as a touchdown sensing device or a fixed
distance standoff.
Air Connection:
Filtered air supply must be precisely regulated and should be set between 1-20 psi
(0.07 to 1.38bar). The air supply is not used as the main dispensing force. It is only
required to move fluid to the feed screw chamber.
Electrical Connection:
The TS5000DMP-DCX Series valve requires an electrical connection of two wires
for the DC motor. The motor lead wires are 24
'' (609.60mm) in length. The black
lead wire should be connected to the negative or neutral lead from the motor
control voltage source. To verify the connection, check the rotation direction of
the feed screw. When correctly connected, a positive voltage signal will drive the
feed screw in a counter clockwise direction when view from the dispense tip end.
The recommended controller for the TS5000DMP-DCX Series valve is the
TS500R. If another controller is used make sure the control voltage signal is
precisely controlled. The signal should be from a regulated power supply and
should be shunted to positive motor stop. Below is a diagram of a simple braking
circuit:
Figure 2.0
11
10.
DMP INSERT OPTIONS
11.
STANDARD ACCESSORIES
11.1 OPTIONAL ACCESSORIES
PART NUMBER DESCRIPTION
DMP6-10 6 Pitch DMP Assembly, Fixed Red Collar, 10 per pack
DMP6R-10 6 Pitch DMP Assembly, Rotating Red Collar, 10 per pack
DMP8-10 8 Pitch DMP Assembly, Fixed Black Collar, 10 per pack
DMP8R-10 8 Pitch DMP Assembly, Rotating Black Collar, 10 per pack
DMP16-10 16 Pitch DMP Assembly, Fixed Blue Collar, 10 per pack
DMP16R-10 16 Pitch DMP Assembly, Rotating Blue Collar, 10 per pack
PART NUMBER DESCRIPTION
5000-000-005 Valve Mounting Bracket
5000-015-000 TS-SS Sample Tip Kit
TS3706 Syringe Bracket Kit
TSD1135-18 6 Pin DIN Socket
71003RHB 10cc Receiver Head, 3ft (0.9M)
73003RHB 30cc Receiver Head, 3ft (0.9M)
PART NUMBER DESCRIPTION
TN00DKIT Complete Dispensing Tip Kit
9000-000-112 Sample Tip Kit
5000-000-082 TS-SS Tip Torque Tool

10
9.
SPARE PARTS
ITEM PART NUMBER DESCRIPTION QTY
1 TSD1415-12 Cable 1
2 TSD1401-7 Bushing 1
3 5000-000-171 Sleeve Cap 1
4 TSD1103-334 Cap Screw 4
5 5000-000-346 Motor Sleeve 1
6 TSD1412-61 Motor 1
7 T1000295 Motor Mounting Plate 1
8 2200-000-011 Square Drive 1
9 TSD1103-330 Mounting Plate Screws 3
10 TSD1103-14 Body Screw, Long 1
11 TSD1103-10 Body Screw, Short 1
12 A0100167 Body For TS5000DMP-DCX 1
12* A0100184 Body For TS5000DMP-DCXL 1
13
See Section 10
DMP Insert 1
NOTE: When replacing the motor (6)
and square drive (8), Loctite #86 AVV
must be used, to bond the square drive
to the motor shaft. The square drive
must be flush with the end of the motor
shaft and any visible excess must be
cleaned off.
Figure 5.0
7
6. TYPICAL SYSTEM SET-UP
Figure 4.0
Dimensions are in
inches (mm)
Figure 3.0
Figure 3.0