M4serviceManual_e.pdf - 第20页

1 Installation 1-12 Pre-Process and Post-Process of Machine Connecting Pre-Process and Post-Process When using other manufacturer’s m achines as the pre-process or post-process, connect them as shown i n the below diagra…

100%1 / 96
1 Installation
1-11
Connecting Loader with Machine
There is an entrance sensor at the entrance of the machine. If the loader is installed upstream of the
machine, the entrance sensor must be moved to avoid interruption with the loader.
After the sensor has been moved, align the conveyors for smooth board transfer.
NOTE: While moving a sensor and aligning conveyors, the power to the machine must be turned off.
a: The sensor position without a loader.
b: The sensor position with a loader installed upstream of the machine.
Loader rack
Loaders frame
Normal position
Entrance Sensor
Position with loader installed
1 Installation
1-12
Pre-Process and Post-Process of Machine
Connecting Pre-Process and Post-Process
When using other manufacturer’s machines as the pre-process or post-process, connect them as shown in
the below diagram. No-voltage output (relay) is recommended for post-process.
Standard spec. : Upper half of the diagram.
SMEMA Interface spec. : Whole diagram.
*INPUT CIRCUIT
*INPUT CIRCUIT
2
1
CN2 CN1
Post-process
Connector (Cable side)
AMP
206044-1(plug)
66099-2 or equivalent (pin)
206070-1(cable clamp)
Connector (Mounter side)
AMP
206043-1(receptacle)
MounterPre-process
BOARD
AVAILABLE
BOARD
AVAILABLE
MACHINE
NOT READY
2.2K Ω
10K Ω
10K Ω
10K Ω
10K Ω
COM
Input
terminal
*INPUT CIRCUIT
+5V
30VDC 1A or less
100VAC 0.5A or less
RELAY
RELAY
MACHINE
NOT READY
3
4
2
1
3
4
1 Installation
1-13
Sequence of Receiving PC board (Standard spec.)
When the machine is ready to receive PC board, Permit Transfer (Machine Not Ready) is sent to
Pre-process machine.
The transfer belt will be activated when the Permit Transfer and the Entrance Sensor turn on.
The Permit Transfer will be sent-off when Entrance Sensor turns on.
The transfer belt will be deactivated when the Arrival Sensor turns on.
“Conveyor Trouble” error happens if the Arrival Sensor does not turn on or the Entrance Sensor does
not turn off within 10 seconds after the transfer belt was activated.