M6e_ServiceManual_e.pdf - 第63页

3 Mechanical Section 3-29 ■ Lubrication Points for M X-20 (Option)

100%1 / 82
3 Mechanical Section
3-28
Application of grease on a Nozzle Holder
ACTION:
Rub the inside of the Nozzle Holder with materials like a dry cotton swab to clean out the grime, such
as old grease.
Use the head vacuum breaker to blow out the dust, such as fibers from a cotton swab.
NOTE: The head vacuum breaker can be executed by clicking the button at required head on the window of Main
Menu > Manual Menu > Actuator > On/Off > Head Vacuum.
Apply silicon grease evenly on the new cotton swab and rub the inside of the Nozzle Holder softly and
evenly with it.
After grease is applied, insert a nozzle and confirm that the nozzle escaping works smoothly.
Nozzle holder
Cotton Swab
3 Mechanical Section
3-29
Lubrication Points for MX-20 (Option)
3 Mechanical Section
3-30
Lubrication Points for MXR-20 (Option)
Linear Shaft
Ball Screw