00195011-01.pdf - 第33页

Installation Manual, Station Software Version 408.01 Edition 03/2006 Description File Old FK_OFF.MA (obsolete) WNK_KORR.MA WPC 80F WPW_80F.MA WPC 80F3 WPW_80F3.MA Nozzle changer Measurement positions PPW_VERM.MA Current …

100%1 / 104
Installation Manual Station Software Version 408.01
4.2 Machine files
Machine-related configuration, measurement and parameter data is stored in *.MA files.
Note:
All machine data must be of revision level 50 (version 408.01). Current machine data mu
s
not be replaced by revision levels of an earlier version, either completely or partially, e.g.
revision level 40 (version 407.01).
Machine files:
Description File
Axis data
Axis option data ACHS_OPT.MA
Axis measurement data ACHS_VER.MA
Axis data ACHS.MA
Axis operation data ACHS_STD.MA
Component removal module setup BEBAND_1.MA
Component removal module setup BEBAND_2.MA
Surf tape feeder data DCA.MA
Operation data for dip module DIPFLUX.MA
Fine calibration offset FK_OFF.MA
Flux dispenser operation data FLUX.MA
Camera setup KAMSTEU.MA
Machine configuration KONFIG.MA
Force steps for head axis KRAFT.MA
Critical ways KRIWEGE.MA
Control data of mapping MAPPSTEU.MA
Machine type definition MATYP.MA
Switchable machine options OPTIONEN.MA
Options reference run REF_LAUF.MA
Parameters of nozzle splitting SCANPAR.MA
Sensor system SST.MA
Board transport TRANSP.MA
Vacuum data of z axis VAK_Z.MA
Vacuum check file VAKUUM.MA
32 of 104
Installation Manual, Station Software Version 408.01 Edition 03/2006
Description File
Old FK_OFF.MA (obsolete) WNK_KORR.MA
WPC 80F WPW_80F.MA
WPC 80F3 WPW_80F3.MA
Nozzle changer
Measurement positions PPW_VERM.MA
Current nozzle changer allocation PPW_AKT.MA
Current nozzle head allocation AKTUELL.MA
Sensor systems
Sensor system individual data KAMDAT.MA
Measurement data
Measurement positions REAL.MA
Nozzle offsets PIP_OFF.MA
Machine configuration, machine configuration options
Machine configuration KONFIG.MA
Machine options MA_OPT.MA
33 of 104
Installation Manual Station Software Version 408.01
4.3 Installing the machine controller M54 (CS, CF, S23, F5 HM)
4.3.1 BIOS Setup
When taking the M54 into service for the first time, the BIOS parameters must be set for the relevant
machine. A configuration file is used in order to automatically modify the data.
The program starts automatically after booting and does not require user input. This resets the
default settings of the BIOS. Thus the configuration remains available even in the event of faults.
After successful installation, the power supply of the control unit should be switched off and then
back on again. The only settings the user will need to make manually in the Setup are the date and
time. The automatic Setup should be called before partitioning or formatting the hard disk.
The floppy disks required for this are created using the file MCBIOS.exe as described in section
4.3.3.1 on page 48). In order to be able to check the settings that have been made, the following
section describes the procedure for a manual Setup and lists the values
NOTE: M54 machine controller with a 30-GB hard disk
Proceed as follows to set up the 30-GB hard disk:
- Call the BIOS setup by pressing F2 immediately the machine is switched on.
- Call up the "AT Hard Disk" setup page.
- Click the "Auto all Drives" button.
The M54 now determines the parameters for the connected hard drive. The following entries are
shown for the 30-GB drive in the "Primary IDE Controller" field:
Master: [ ] USR1 3648 255 63 None ??? ??? LBA [ ] [ ] [ ]
- Close the BIOS setup with "Exit" and "Save".
Information: The original partitions are displayed correctly, but to not function correctly.
Simply reformatting the disk does not solve the problem.
- Create with FDISK follwowing partitions:
Partition Status Typ Mbyte
C:1 A PRI DOS 50
2 EXT DOS 450
- Restart the computer (Press simultaneously Ctrl + Alt + Del).
- Now the 505 software can be installed in the normal manner for a new hard disk.
34 of 104