00195011-01.pdf - 第34页
Installation Manual Station Software Version 408.01 4.3 Installing the machine controller M54 (CS, CF , S23, F5 HM) 4.3.1 BIOS Setup When taking the M54 into service for the first time, the BIOS parameters must be set fo…

Installation Manual, Station Software Version 408.01 Edition 03/2006
Description File
Old FK_OFF.MA (obsolete) WNK_KORR.MA
WPC 80F WPW_80F.MA
WPC 80F3 WPW_80F3.MA
Nozzle changer
Measurement positions PPW_VERM.MA
Current nozzle changer allocation PPW_AKT.MA
Current nozzle head allocation AKTUELL.MA
Sensor systems
Sensor system individual data KAMDAT.MA
Measurement data
Measurement positions REAL.MA
Nozzle offsets PIP_OFF.MA
Machine configuration, machine configuration options
Machine configuration KONFIG.MA
Machine options MA_OPT.MA
33 of 104

Installation Manual Station Software Version 408.01
4.3 Installing the machine controller M54 (CS, CF, S23, F5 HM)
4.3.1 BIOS Setup
When taking the M54 into service for the first time, the BIOS parameters must be set for the relevant
machine. A configuration file is used in order to automatically modify the data.
The program starts automatically after booting and does not require user input. This resets the
default settings of the BIOS. Thus the configuration remains available even in the event of faults.
After successful installation, the power supply of the control unit should be switched off and then
back on again. The only settings the user will need to make manually in the Setup are the date and
time. The automatic Setup should be called before partitioning or formatting the hard disk.
The floppy disks required for this are created using the file MCBIOS.exe as described in section
4.3.3.1 on page 48). In order to be able to check the settings that have been made, the following
section describes the procedure for a manual Setup and lists the values
NOTE: M54 machine controller with a 30-GB hard disk
Proceed as follows to set up the 30-GB hard disk:
- Call the BIOS setup by pressing F2 immediately the machine is switched on.
- Call up the "AT Hard Disk" setup page.
- Click the "Auto all Drives" button.
The M54 now determines the parameters for the connected hard drive. The following entries are
shown for the 30-GB drive in the "Primary IDE Controller" field:
Master: [√ ] USR1 3648 255 63 None ??? ??? LBA [ ] [ ] [ ]
- Close the BIOS setup with "Exit" and "Save".
Information: The original partitions are displayed correctly, but to not function correctly.
Simply reformatting the disk does not solve the problem.
- Create with FDISK follwowing partitions:
Partition Status Typ Mbyte
C:1 A PRI DOS 50
2 EXT DOS 450
- Restart the computer (Press simultaneously Ctrl + Alt + Del).
- Now the 505 software can be installed in the normal manner for a new hard disk.
34 of 104

Installation Manual, Station Software Version 408.01 Edition 03/2006
Note:
Y
ou find more details concerning the BIOS setting, operating system etc. in o
Technical Information that are online available via the SIEMENS DMS
(
www.siplace.com
).
4.3.1.1 Starting the BIOS Setup
To start the BIOS setup, wait for the following message to appear on the screen after the system
has been booted and then press the <F2> key.
PowerBIOS Version 1.00
Copyright(C) 1984-1995, Award Software, Inc.
12/06/96 - Intel - 82430HX
AMS-M54 V 1.00
┌────────────────────────────────────────────────────────────────────────┐
│ CPU Type...............................................Pentium xxx MHz │
│ Math CoProcessor..............................................Internal │
│ . │
│ . │
│ . │
│ . │
│ . │
│ . │
│ . │
│ . │
└────────────────────────────────────────────────────────────────────────┘
Press F2 to enter setup
35 of 104