00191374-04.pdf - 第118页

6 Gantries Adjust men t Ins tru ct ion s SIPL ACE H S-50 6.4 Settings and I llustrations Edition 12/00 118 3UR[L PLW\ VZLWFK; 3 UR[LPLW \VZLWFK;  gantry 1 top bottom gantry 2 bottom top gantry 3 top bottom gantry 4…

100%1 / 186
Adjustment Instructions SIPLACE HS-50 6 Gantries
Edition 12/00 6.4 Settings and Illustrations
117
 3UR[LPLW\6ZLWFK&RQQHFWRUVRQWKH;<'LVWULEXWRU6
.(<
;;=Proximity switch y-axis
; = Distance sensor
; = Track signals y-axis
(1) Switch point end position
(2) Switch point reference
(3) Switch point reference
(4) Switch point end position
6FKDOWSXQNWH5HIHUHQ]SXQNWXQG(QGODJHQlKHUXQJVVFKDOWHU
VZLWFKSRLQWVUHIHUHQFHSRLQWDQGHQGSRVLWLRQOLPLWVZLWFK
1
2
3
4
6 Gantries Adjustment Instructions SIPLACE HS-50
6.4 Settings and Illustrations Edition 12/00
118
3UR[LPLW\VZLWFK; 3UR[LPLW\VZLWFK;
gantry 1 top bottom
gantry 2 bottom top
gantry 3 top bottom
gantry 4 bottom top
distance sensor X9 only with gantry 1 and 3
6ZLWFKSRLQWV5HIHUHQFHHQGSRVLWLRQ
1 switch point: end position gantry 2 , 4
2 switch point: reference gantry 2, 4
3 switch point: reference gantry 1, 3
4 switch point: end position gantry 1, 3
Adjustment Instructions SIPLACE HS-50 6 Gantries
Edition 12/00 6.5 Dynamic Adjustment of the X- and Y- Axes
119
 '\QDPLF$GMXVWPHQWRIWKH;DQG<$[HV
NOTE
Gantry 1 serves to exemplify all SITEST functions.
 (TXLSPHQWDQG7HVW'HYLFHV
2 or 4 channel storage oscilloscope.
SIPLACE axis test box, complete.
SITEST software.
NOTE
The machine must have reached its operating temperature before you begin to adjust the axes.
Therefore, make sure to switch it on, at least 30 minutes before you begin to work.
 6HUYR%RDUGV*DQWU\$[HV+6
TBS 200 / 10X
TBS 200 / 15Y