00191374-04.pdf - 第128页
6 Gantries Adjust men t Ins tru ct ion s SIPL ACE H S-50 6.5 Dynamic Adjustment of the X- and Y- Axes Edition 12/00 128 Sollwert / Vnomina l Positi onsabweich ung / deviation of posit ion S tromsollwert / nomi nal curren…

Adjustment Instructions SIPLACE HS-50 6 Gantries
Edition 12/00 6.5 Dynamic Adjustment of the X- and Y- Axes
127
Sollwert /
Vnominal
Positionsabweichung /
deviation of position
Kraftsollwert /
nominal current
Endemeldung /
end signal
&KDQQHO 6LJQDO &RXSOLQJ <'HIOHFWLRQ 7ULJJHU ;'HIOHFWLRQ
CH 1 Vnominal DC 1 V/ DIV
Ch1
positive
3% pre
10 ms/ DIV
CH 2 deviat. of pos. DC 0.5 V/ DIV
CH 3 nominal current DC 5.0 V/ DIV
CH 4 end signal DC 5.0 V/ DIV

6 Gantries Adjustment Instructions SIPLACE HS-50
6.5 Dynamic Adjustment of the X- and Y- Axes Edition 12/00
128
Sollwert /
Vnominal
Positionsabweichung /
deviation of position
Stromsollwert /
nominal current
Endemeldung /
end signal

Adjustment Instructions SIPLACE HS-50 6 Gantries
Edition 12/00 6.6 Calibration of the Anti - Crash Board
129
&DOLEUDWLRQRIWKH$QWL&UDVK%RDUG
7HVW(TXLSPHQW
– Digital multimeter
– SITEST software
– Anti - crash board for HS-50
7HVW6HWXS
.(<
TP2 = Signal
R82, R92 = Potentiometer
TP1 = Signal
X
, Y = "Error" message for the axes of the left gantry in each work area.
X
, Y = "Error" message for the axes of the right gantry in each work area.
(Viewpoint from input conveyor).
DIS = Message: Distance sensor activated.
R 82
R 92