2-13 2 Basic operation n M a n u a l h e a d o p e r a t i o n [Unit] – [Head] screen 1 2 3 4 5 6 7 24 2 1 8 - M 1 -0 0 B u t t o n n a m e F u n c t i o n 1 Vac u u m T u r n s t h e v a c u u m o f e a c h h e a d o n …

100%1 / 116
2-12
2
Basic operation
n
Axis movement
"Move Axis" screen
1
2
3
4
5
6
24215-M0-00
Button name Function
1 Zoom in/out (+, -) Zooms in or out the image. (16 times to 1/16 times)
2 Mark Light Allows changing mark lighting manually. Using this button does not affect data.
3 PTP
Displays the "PTP" dialog box that allows directly specifying the position where
you want to move the selected axis.
4 Step Mode
When this button is pushed in, the selected axis can be moved in "step mode
(inching mode)" with the arrow buttons at a specified step stroke (inching
stroke).
5 Arrow Use these buttons to move the selected axis in the desired direction.
6 Brake
Use this button when you want to release the brake during emergency stop.
(W-axis and PU axis only)
The brake is automatically released when the servo is turned on.
2-13
2
Basic operation
n
Manual head operation
[Unit] – [Head] screen
1
2
3
4
5
6
7
24218-M1-00
Button name Function
1 Vacuum Turns the vacuum of each head on or off.
2 Blow Turns the air blow in each head on or off.
3 Nozzle STN Shutter Opens or closes the nozzle station shutter.
4 Nozzle Change
Opens the "Nozzle Change" dialog box.
Specify the head and nozzle type to
perform nozzle change.
5 Current Nozzles
Shows a list of nozzle types currently
attached to each head.
6 Axis
Opens the "Move Axis" screen. This is the same as the [Axis] button on the [Unit]-
[Conveyor] screen.
7 Cleaning Blow Displays a confirmation dialog box for nozzle shaft blow.
2-14
2
Basic operation
n
Manual feeder operation
[Unit] – [Feeder] screen
3 4
1
2
24222-M0-00
Button name Function
1 Left/right arrows Scrolls through the drive valve number display.
2 Up/down arrows
Switches the drive valve number display between the front and rear
sides.
3 Drive valve Turns the feeder shutter drive valve on or off.
4 Reset Turns off all drive valves at a time.